TG 209 F1 Libra® Thermogravimetric Analyzer from NETZSCH-Gerätebau GmbH

Get Quote

Get Quote from
NETZSCH-Gerätebau GmbH for
TG 209 F1 Libra® Thermogravimetric Analyzer

Description

The vacuum-tight thermo-microbalance for highest demands

Flexibility with the fittings of this premium instrument for thermogravimetric analysis allow it to cover almost any imaginable application in the range up to 1100°C. The system has many outstanding features: BeFlat® function allows or immediate measurement upon switching on the unit, the system’s heating rates of up to 200 K/min allow for faster results, while its corrosion-resistant ceramic furnace withstands even fluorine- or chlorine-containing polymers, c-DTA® function for the detection of exothermal and endothermal reactions.

Faster and more comprehensive characterization of materials
Based on over 50 years of experience in thermogravimetric analysis, NETZSCH has developed the thermo-balance TG 209 F1 Libra®. This instrument allows for analyses to be carried out even faster, more accurately, and across an extended temperature range.

Twice as fast by means of BeFlat®
In contrast with other thermo-balances, no time-consuming baseline determinations need normally to be carried out with the TG 209 F1 Libra® prior to a measurement. The unique BeFlat® function of the TG 209 F1 Libra® automatically compensates for any external factors influencing the measurement. This cuts work hours by up to 50%, leaving more time available, for example, for further measurements.

20 times faster due to high heating rates
The heart of the TG 209 F1 Libra® is the micro furnace made of high-performance ceramics. It not only allows for a wider sample temperature range of up to 1100°C, but also for heating rates of up to 200 K/min. The user can thus receive the results of the analysis – even at highest temperature – within a few minutes, i.e. 20 times faster than for other thermo-balances.

More comprehensive and faster characterization by patented c-DTA®
With the TG 209 F1 Libra®, the sample temperature is measured directly. Endo- and exothermal reactions can now be detected and show, for example, the melting point of the sample, in the evaluation. This yields considerably more information on the sample behavior without having to carry out further measurements.

High-performance ceramics for a long lifespan
The lifespan of the new, especially designed ceramic furnace – even when investigating materials containing corrosive components – is many times longer than that of conventional thermo-balances. The analysis of fluorinated or chlorinated polymers is therefore no problem. The reaction and purge gases flow in the natural, vertical direction. Condensation on measure-relevant components (sample holders) can therefore be excluded. This not only is gentle on the material, but also prevents occurrence of the dreaded memory effect which can distort subsequent measurements in conventional systems.