Description | The AccuSizer is a sophisticated high-resolution particle counter and particle size analyzer that uses the technique of singal particle optical sizing (SPOS). The major benefits of this technique include:
- High Accuracy: Each particle is measured directly
- Concentratation: accurate particles/mL
The AccuSizer is a sophisticated high-resolution particle counter and particle size analyzer that uses the technique of singal particle optical sizing (SPOS). The major benefits of this technique include:
- High Accuracy: Each particle is measured directly
- Concentratation: accurate particles/mL results
- Resolution: no distribution broadening, split multiple peaks to baseline, detect small concentration of tails
AccuSizer FX-Nano AD System
- Uses LE400 plus FX-Nano sensors with AD-style exponential autodilution down to 150 nm
- Can analyze high concentration samples up to 106 particles/mL
- Ideal for filter testing and high concentration protein samples
... Read More | The AccuSizer is a sophisticated high-resolution particle counter and particle size analyzer that uses the technique of singal particle optical sizing (SPOS). The major benefits of this technique include:
- High Accuracy: Each particle is measured directly
- Concentratation: accurate particles/mL
The AccuSizer is a sophisticated high-resolution particle counter and particle size analyzer that uses the technique of singal particle optical sizing (SPOS). The major benefits of this technique include:
- High Accuracy: Each particle is measured directly
- Concentratation: accurate particles/mL results
- Resolution: no distribution broadening, split multiple peaks to baseline, detect small concentration of tails
AccuSizer AD System - Patented Autodilution
- The most popular for general particle size analysis applications
- Performs exponential autodilution while providing accurate concentration information
The autodilution system includes an input, output, dilution chamber, sample material, and diluent. A known quantity of sample material is injected into the dilution chamber. Filtered diluent flows into the dilution chamber, mixes with the sample material, and continuously dilutes the initial concentration. The diluted sample then flows out of the dilution chamber and through the sensor for particle size and count analysis.... Read More | A comprehensive portfolio of high accuracy and resolution liquid particle counters that determine particle size and concentration of your suspensions.
Features:
- Uses single particle optical sizing (SPOS) technology to provide extended dynamic size and concentration ranges
-
Can be used as a liquid
A comprehensive portfolio of high accuracy and resolution liquid particle counters that determine particle size and concentration of your suspensions.
Features:
- Uses single particle optical sizing (SPOS) technology to provide extended dynamic size and concentration ranges
-
Can be used as a liquid particle counter for contamination applications or as sophisticated particle size analyzer
-
Highest sensitivity technology available to determine tails of distribution such as large particle counts (LPC) in CMP slurries, protein aggregates, or tails of emulsions (PFAT5)
-
Fast, multi-channel pulse height analyzers that can report results in up to 1024 size bins
-
Several fluidics configurations are available to deliver the sample to the sensor directly or with auto dilution to avoid coincidence errors
... Read More | Nanoparticles are now standard materials for many industrial products. Like most other processes, the production of nano-particles needs to be measured in order to be controlled. Dynamic light scattering (DLS) measurements have traditionally been performed using laboratory instruments like the Nanoparticles are now standard materials for many industrial products. Like most other processes, the production of nano-particles needs to be measured in order to be controlled. Dynamic light scattering (DLS) measurements have traditionally been performed using laboratory instruments like the Entegris Nicomp system, but the Entegris particle sizing team also has many years of online experience. The Mini DLS builds on these years of experience to develop a flexible and elegant solution that can be adapted to a wide range of nanoparticle manufacturing processes including milling, homogenizing, or self-assembly.
On-line particle size analyzer for nanoparticles and emulsions from 20 nm to 2 µm
- Flexible protocols to optimize measurement to application based on dynamic light scattering (DLS)
- Automated sampling and measurement to eliminate operator and lab resources
- Continuous data to track changes in particle size distribution
- Easy data transfer to process monitoring control software
... Read More | ZETA POTENTIAL ANALYZER
Nicomp Nano Z3000 System
Combines Dynamic Light Scattering (DLS) sizing capability with both frequency and Phase Analysis Light Scattering (PALS) modes for measuring zeta potential
With an electric field that can be varied from 1 to 250 Volts/cm, one instrument can be used ZETA POTENTIAL ANALYZER
Nicomp Nano Z3000 System
Combines Dynamic Light Scattering (DLS) sizing capability with both frequency and Phase Analysis Light Scattering (PALS) modes for measuring zeta potential
With an electric field that can be varied from 1 to 250 Volts/cm, one instrument can be used to analyze zeta potential in aqueous and organic solvents
Cost of ownership is minimized with easy-to-use dip cell and inexpensive ZRS zeta potential standard
Standard Zeta Features
- Phase Analysis Light ScatteringPat. – utilizing a DSP based PALS technique to measure small doppler shifts in the phase of the light scattered from a suspension allowing you to determine the zeta potential in high ionic strength or high dielectric environments (organics).
- Frequency Analysis Mode – provides a frequency domain zeta measurement. This is very useful in obtaining distribution information on the mean zeta potential value as well as a great tool for providing information on the system alignment in service mode.
- Dip Cell Electrodes – these electrodes can be dipped directly into a disposable cuvette which provides for a uniform electric field between the electrode pair, eliminating the need for the stationary plane determination. These electrodes are made from a rugged palladium tip design which provides a durable dip cell design that has a long-life cycle.
- High Voltage Zeta Potential Cell – measures at higher electric field strengths (up to 250V/cm) in organic solvents.
- Electric Field Strength Compensation – Constant current mode that compensates for fall in the electric field during a sample analysis.
- Polarization Correction – provides a correction for the polarization effects in the Phase Analysis Mode PALS to provide an accurate zeta potential value.
... Read More |
Detector(s) | Focused beam, scatter 0.15-10+ µm at high concentration | Extinction, Scattering, Collimated, and/or Focused (sensor dependent) | Extinction and Scattering | Inquire | 15 – 100 mW red laser diodes, 20 – 100 mW green laser diodes |
Applications | Materials Testing, Pharmaceutical Lab | Materials Testing, Pharmaceutical Lab | Inquire | Submicron suspensions and emulsions | Materials Testing, Pharmaceutical Lab |