Particle Size Analyzer (Particle Analyzers / Particle Sizer)

Particle analyzers are used to determine the size and distribution of particles making up a material. Particle size analyzers are used in numerous fields for research and development, manufacturing and for quality control and product testing. Different technologies enable analysis across a wide range of sizes, of particles in powder, liquid, aerosol or other forms, and of materials ranging in diversity from soil, paint and cosmetics to nasal spray and proteins.

Laser diffraction particle size analyzers calculate particle size from the angle of light scattered by a stream of particles passing through a laser beam. This technique allows for continuous measurement of bulk material across a wide size range (10 nm to 3 mm). The size limits and sensitivity of a laser diffraction particle analyzer depend on the number and placement of detectors in the instrument. Dynamic light scattering particle analyzers are mainly used for analyzing particles in solution (size range: 1 nm to 6 um). Dynamic light scattering determines size from the fluctuations in scattered laser light intensity created by the particles’ Brownian motion. Induced grating particle size analyzers identify the size of even smaller particles (0.5 nm to 200 nm) in solutions by electrically aligning the particles and then measuring their diffusion.

Find, compare, and request a quote for particle size analyzers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

CompanyWaters | Wyatt TechnologyWaters | Wyatt TechnologyWaters | Wyatt TechnologyWaters | Wyatt TechnologyWaters | Wyatt Technology
ItemDAWN™ Multi-angle Light Scattering (MALS) InstrumentDynaPro™ NanoStar™ II Dynamic Light Scattering InstrumentDynaPro™ ZetaStar™ Dynamic, Electrophoretic, and Static Light Scattering InstrumentmicroDAWN™ Multi-Angle Light Scattering Instrument for UHP-SEC-MALSminiDAWN™ Multi-Angle Light Scattering (MALS) Detector for SEC-MALS
Citations
(1)
Reviews
Catalog NumberDAWNDynaPro NanoStar IIDynaPro ZetaStarmicroDAWNminiDAWN
Price
DescriptionThe DAWN™ instrument is an advanced detector for precise characterization of proteins, polymers, and nanoparticles including viral vectors, lipid nanoparticles and vesicles. Using multi-angle static light scattering (MALS) and optional dynamic light scattering (DLS), DAWN analyzes molar mass... Read MoreThe DynaPro™ NanoStar™ II is the only DLS instrument to provide a fully integrated, walk-up measurement experience so even novices can immediately measure particle concentration, characterize size, aggregation, quality solubility, and stability of proteins, viruses, or nanoparticles in ... Read MoreUnique among its peers, the DynaPro™ Zetastar™ performs simultaneous dynamic and static light scattering or dynamic and electrophoretic light scattering (DLS/SLS/ELS) measurements all within one instrument. Measure manually with microcuvettes, or automatically via an autosampler and flow... Read MoreThe microDAWN™ MALS detector performs absolute characterization of macromolecules eluting from UHPLC (or UPLC), determining molar mass and size independently of retention time and molecular reference standards. This instrument offers superb sensitivity over a wide range of molar mass, size and... Read MoreCouple the miniDAWN™ to your favorite HPLC or FPLC to determine the absolute molar masses and sizes of macromolecules and nanoparticles in solution from hundreds to millions of Daltons—without the need for column calibration standards. This sensitive unit requires as little as 25 ng injected ... Read More
TypeMALS and optional DLSDynamic Light Scattering (DLS) and Static Light Scattering (SLS)Dynamic Light Scattering (DLS), Electrophoretic Light Scattering (ELS), Static Light Scattering (SLS)MALS and optional DLSMALS and optional DLS
Particle SizeInquire0.2 to 1000 nm0.2 to 1000 nmInquireInquire
Detector(s)High-gain, high-dynamic-range photodiodes at 18 angles for MALS; optional avalanche photodiode that may be placed at any of four angles for DLS.
Fluorescence-blocking filters available for use with analytes that fluoresce when illuminated at the MALS wavelength.
InquireInquireHigh-gain, high dynamic range, static light scattering detectors at 3 anglesHigh-gain, high-dynamic range photodiodes at 3 detection angles for MALS. Optional avalanche photodiode for simultaneous dynamic light scattering measurements.
Measuring TimeDepedent on LC separationInquire15 seconds typicalDepedent on LC separationDepedent on LC separation
Light Source658 nm laser, programmable 10% - 100% of maximum power.

Optional: 785 nm for fluorescence suppression
Inquire785 nm laser, programmable 10% to 100%660 nm laser, programmable 10% - 100% of maximum power.658 nm laser, programmable from 10% to 100% maximum power.
ApplicationsWith standard SEC/GPC or EclipseTM (FFF system): determination of distributions of molar mass, size, conformation, conjugation ratio and particle concentration. With Calypso composition-gradient system: label-free characterization of biomolecular interactions including self- and hetero-association as well as non-specific interactions.InquireAnalysis of proteins, gene vectors, viruses and virus-like particles, promiscuous inhibitors, micelles, nano-emulsions, lipid and metallic nanoparticles, and more.With SEC/GPC: determination of distributions of absolute molar mass, size, conformation, conjugate ratio.With SEC/GPC: determination of distributions of absolute molar mass, size, conformation, conjugate ratio. With Calypso CG-MALS: characterization of biomolecular interactions.
Get Quote