Total Organic Carbon Analyzer (TOC Analyzers)

Total Organic Carbon Analyzer (TOC Analyzers) A total organic carbon analyzer (also referred to as TOC analyzers) measures the amount of total organic carbon present in a liquid or water sample. TOC detection is important because of the effects that TOCs may have on health, not to mention the environmental effects and implications for the pharmaceutical manufacturing processes. Since all total organic carbon analyzers only measure total carbon, a TOC analyzer always requires some accounting for the inorganic carbon (IC) that is always present. TOC analyzers, including a portable TOC analyzer, utilize the same basic technique where acid is added to the liquid sample to remove IC. At this point, the IC is converted into carbon dioxide gas. It is then stripped out of the liquid by a carrier gas where the remaining inorganic carbon-free sample is then oxidized and the carbon dioxide generated from the oxidation process is directly related to the TOC total organic carbon in the sample. There are several methods for introducing the sample to TOC analyzers, including using a syringe, autosampler, and loop sampling. An important specification for total organic carbon analyzers is the measuring range. Carrier gas flow rate, average analysis time and process temperature are important as well for total organic carbon analysis.

Find, compare, and request a quote for total organic carbon analyzers (TOC analyzers) across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

Your search for tOC returned 48 results.
Showing 40 of 48 products
Get Quote for All
Select up to 5 products from below to compare or request more information.

Sponsored Products

TOC-VWS Wet Oxidation TOC Analyzer
Shimadzu
  • Measurement Mode(s):
    TC, IC, TOC, NPOC
  • Oxidation Method:
    Wet Chemical (Heat-UV-Persulfate)
  • Measuring Range:
    TC: 0-3,500 mg/L, IC: 0-3,500 mg/L
  • Detection Limit:
    0.5 µg/L
  • Measuring Time:
    ~ 4 minutes
Citations:
(82)
TOC-L Series Total Organic Carbon Analyzers
Shimadzu
  • Measurement Mode(s):
    TC, IC, TOC and NPOC;
    (POC, TOC via POC + NPOC and TN : Optional)
  • Oxidation Method:
    Combustion Catalytic Oxidation Method
    (Non-Dispersive Infrared detection Method)
  • Measuring Range:
    TC: 0 to 30,000 mg/L, IC: 0 to 35,000 mg/L
  • Detection Limit:
    4 or 50 ug/L (TC)
  • Measuring Time:
    3 or 4 min
Citations:
(252)
TOC-1000e Online TOC Analyzer for Pure Water Analysis
Shimadzu
  • Measurement Mode(s):
    TOC, conductivity (or specific resistance), and temperature
  • Measuring Range:
    TOC: 0 to 2000 µg/L; Conductivity: 0.023 to 206 µS/cm (without temperature correction)
  • Detection Limit:
    TOC: 0.1 µg/L
  • Measuring Time:
    2.5 min, 5 min, 10 min, 15 min, 30 min, 1 hr, 2 hrs, 4 hrs, 12 hrs, or 24 hrs measurement cycle
Citations:
(1)
TOC-4200 Online Total Organic Carbon Analyzer
Shimadzu
  • Measurement Mode(s):
    TC, NPOC, IC-POC M, TN
  • Oxidation Method:
    Combustion Oxidation / Non-Dispersive Infrared Gas Detection
  • Measuring Range:
    5 to 20,000 mgC/L
  • Detection Limit:
    Inquire
  • Measuring Time:
    4 min
Citations:
(12)
multi X® 2500 AOX/TOX Analyzer
Analytik Jena
  • Measurement Mode(s):
    Microcoulometry, NDIR, for AOX, EOX, POX, TOC, TX/TOX
  • Oxidation Method:
    Combustion
  • Measuring Range:
    AOX/ EOX/ POX/ TX/ TOX determination - up to 1,000 µg Cl absolute
    TOC determination - up to 10,000 mg/l TOC
  • Detection Limit:
    AOX/ EOX/ POX/ TX/ TOX determination - 10 ng Cl absolute
    TOC determination - 0.2 mg/l
  • Measuring Time:
    AOX/EOX/TX: approx. 8 - 10 min depending on concentration and application
    TOC: approx. 3 - 5 min depending on concentration and application
Citations:
(2)
multi EA® 4000 for Macro-Elemental Analysis
Analytik Jena
  • Measurement Mode(s):
    TC, TOC, TIC, EC and BOC
  • Oxidation Method:
    High-temperature combustion
  • Measuring Range:
    0 – 100 % C at 0.5 g sample or 500 mg C absolute
    0 – 20 % S at 75 mg sample or 15 mg S absolute
    0 – 10 % Cl at 100 mg sample or 10 mg Cl absolute
  • Detection Limit:
    Carbon - 3 ppm at 3 g sample weight or 10 µg C abs | Sulfur - 3 ppm at 3 g sample weight or 10 µg S abs. | Chlorine - 0.3 ppm at 3 g sample weight or 1 µg Cl abs.
  • Measuring Time:
    C/S determination (simultaneous or separate): at least 3 minutes, Cl determination: 3 - 10 minutes
Citations:
(13)
multi EA® 5100 for Micro-Elemental Analysis
Analytik Jena
  • Measurement Mode(s):
    TOC, EOX or AOX/TOX
  • Oxidation Method:
    Combustion
  • Measuring Range:
    Carbon - 100 wt-% (organics) 10,000 mg/L (water), Nitrogen - 10,000 mg/L, Sulfur - 40,000 mg/L, Chlorine - 100,000 mg/L
  • Detection Limit:
    Carbon - 100 µg/L (organics) 200 µg/L (water), Nitrogen - 10 µg/L, Sulfur - 5 µg/L, Sulfur - 600 µg/L, Chlorine - 50 µg/L (“high sensitive”)
  • Measuring Time:
    Approx. 3 – 5 min (V) C/N/S, 3 – 8 min C/N/S (H) and Cl (V/H)
TOC Sensor 6000TOCi On-Line TOC Analyzer
Mettler Toledo
  • Measurement Mode(s):
    TOC (continuous online)
  • Oxidation Method:
    UV oxidation
  • Measuring Range:
    0.05–2,000 ppbC (µgC/L)
  • Detection Limit:
    0.025 ppbC
  • Measuring Time:
    <60 s response time
450TOC Portable TOC Analyzer
Mettler Toledo
  • Measurement Mode(s):
    TOC (portable at-line)
  • Oxidation Method:
    UV oxidation
  • Measuring Range:
    0.05–1,000 ppbC (µgC/L)
  • Detection Limit:
    0.025 ppbC
  • Measuring Time:
    60 s response time
TOC-1000e S Online TOC Analyzer
Shimadzu
  • Measurement Mode(s):
    Inquire
  • Oxidation Method:
    680°C Combustion Catalytic Oxidation
  • Measuring Range:
    Inquire
  • Detection Limit:
    0.1 µg/L
  • Measuring Time:
    Inquire
TOC-VWP Wet Oxidation TOC Analyzer
Shimadzu
  • Measurement Mode(s):
    Inquire
  • Oxidation Method:
    Wet Oxidation (persulfate + UV)
  • Measuring Range:
    Inquire
  • Detection Limit:
    4 µg/L
  • Measuring Time:
    Inquire
BioTector B3500ul Online TOC Analyzer
Hach Company
  • Measurement Mode(s):
    TIC, TOC (NPOC), TC, VOC
  • Oxidation Method:
    Two Stage Advanced Oxidation Technology (UV/chemical)
  • Measuring Range:
    80–5,000 µg/L C
  • Detection Limit:
    Inquire
  • Measuring Time:
    Inquire
BioTector B7000 Online TOC/TN/TP Analyzer
Hach Company
  • Measurement Mode(s):
    TOC, TIC, TC, TN, TP, VOC
  • Oxidation Method:
    Two Stage Advanced Oxidation Technology (UV/chemical)
  • Measuring Range:
    0–25 mg/L to 0–10,000 mg/L (configurable)
  • Detection Limit:
    Inquire
  • Measuring Time:
    Inquire
BioTector B3500c Online TOC Analyzer
Hach Company
  • Measurement Mode(s):
    TIC, TOC (NPOC), TC, VOC
  • Oxidation Method:
    Two Stage Advanced Oxidation Technology (UV/chemical)
  • Measuring Range:
    0–25 mg/L C or 0–100 mg/L C (user selectable)
  • Detection Limit:
    Inquire
  • Measuring Time:
    Inquire
BioTector B3500dw Online TOC Analyzer
Hach Company
  • Measurement Mode(s):
    TIC, TOC (NPOC)
  • Oxidation Method:
    Two Stage Advanced Oxidation Technology (UV/chemical), EPA method approved
  • Measuring Range:
    0–25 mg/L C
  • Detection Limit:
    Inquire
  • Measuring Time:
    Inquire
Aurora 1030W TOC Analyzer
OI Analytical
  • Measurement Mode(s):
    TOC, TC, TIC, NPOC
  • Oxidation Method:
    Heated sodium persulfate wet oxidation (100°C)
  • Measuring Range:
    10 ppb C – 30,000 ppm C
  • Detection Limit:
    2 ppb C (IDL)
  • Measuring Time:
    Inquire
QbD1200+ Laboratory TOC Analyzer
Beckman Coulter Life Sciences
  • Measurement Mode(s):
    TOC, IC removal (NPOC)
  • Oxidation Method:
    Precision-controlled UV oxidation
  • Measuring Range:
    1–5,000 ppb (extendable to 100,000 ppb via 20× auto-dilution)
  • Detection Limit:
    1 ppb
  • Measuring Time:
    120 min calibration routine
BioTector B3500e Online TOC Analyzer
Hach Company
  • Measurement Mode(s):
    TIC, TOC (NPOC), TC, VOC
  • Oxidation Method:
    Two Stage Advanced Oxidation Technology (UV/chemical), self-cleaning reactor
  • Measuring Range:
    0–250 mg/L C (standard); 0–1,000 ppm with extended range option
  • Detection Limit:
    Inquire
  • Measuring Time:
    Inquire
BioTector B7000i Online TOC Analyzer
Hach Company
  • Measurement Mode(s):
    TIC, TOC (NPOC), TC, VOC
  • Oxidation Method:
    Two Stage Advanced Oxidation Technology (UV/chemical), self-cleaning oversized tubing
  • Measuring Range:
    0–10,000 mg/L C
  • Detection Limit:
    Inquire
  • Measuring Time:
    Inquire
BioTector B7000i Dairy Online TOC Analyzer
Hach Company
  • Measurement Mode(s):
    TIC, TOC (NPOC), TC, VOC
  • Oxidation Method:
    Two Stage Advanced Oxidation Technology (UV/chemical), dairy-specific self-cleaning tubing
  • Measuring Range:
    0–20,000 mg/L C
  • Detection Limit:
    Inquire
  • Measuring Time:
    Inquire
YSI 9220 Total Organic Carbon Analyzer
OI Analytical
  • Measurement Mode(s):
    TOC, TIC
  • Oxidation Method:
    Heated sodium persulfate oxidation
  • Measuring Range:
    0–25 ppm (standard); adjustable up to 100 ppm
  • Detection Limit:
    0.015 ppm (15 ppb)
  • Measuring Time:
    5–9 minutes per sample interval
CHS-580A Carbon / Hydrogen / Sulfur Analyzer with Autoloader
ELTRA
  • Measurement Mode(s):
    Carbon, Hydrogen, Sulfur
  • Oxidation Method:
    Thermal Combustion
  • Measuring Range:
    0.005 – 100 %
  • Detection Limit:
    Inquire
  • Measuring Time:
    60 - 180 s
Citations:
(1)
multi N/C pharma
Analytik Jena
  • Measurement Mode(s):
    TOC, NPOC, TC, TIC; optional TNb (chemiluminescence, CLD) for combustion models; multi N/C 2100S pharma: TN only for total protein determination
  • Oxidation Method:
    pharma UV: UV wet chemical digestion (254 nm + 185 nm, High Power Long Life UV reactor); pharma HT and 3100 pharma: thermocatalytic high-temperature combustion up to 950°C
  • Measuring Range:
    pharma UV: 1 µg/L – 10,000 mg/L C; 3100 pharma: 4 µg/L – 30,000 mg/L C; 2100S pharma: 5 µg/L – 200 mg/L TN
  • Detection Limit:
    pharma UV: 1 µg/L C (ultra-trace without persulfate); pharma HT: 4 µg/L C; 3100 pharma: 4 µg/L C; 2100S pharma: 5 µg/L TN
  • Measuring Time:
    Inquire
multi N/C 4300 UV
Analytik Jena
  • Measurement Mode(s):
    TC, TIC, TOC, DOC, NPOC, NPOCplus; optional solids TC/TOC/TIC (no TNb)
  • Oxidation Method:
    UV wet chemical digestion (high-power UV reactor, 254 nm and 185 nm wavelengths); optional non-catalytic high-temperature combustion up to 1300°C for solids (HT 1300 module)
  • Measuring Range:
    0–10,000 mg/L C
  • Detection Limit:
    1 µg/L C
  • Measuring Time:
    3–5 min/sample
ELEMENTRAC&reg; CHS-r Carbon / Hydrogen / Sulfur Analyzer
ELTRA
  • Measurement Mode(s):
    Carbon, Hydrogen, Sulfur
  • Oxidation Method:
    Thermal Combustion
  • Measuring Range:
    25 to 500 mg (carbon), 10 to 100 mg (sulfur)
  • Detection Limit:
    Inquire
  • Measuring Time:
    60 - 180 s
ELEMENTRAC&reg; CS-r Carbon / Sulfur Analyzer for Organic Samples
ELTRA
  • Measurement Mode(s):
    Sulfur, Carbon
  • Oxidation Method:
    Thermal Combustion
  • Measuring Range:
    25 to 500 mg (carbon), 10 to 100 mg (sulfur)
  • Detection Limit:
    5 ug (carbon), 1 ug (sulfur)
  • Measuring Time:
    60 to 120 s
multi N/C 3300
Analytik Jena
  • Measurement Mode(s):
    TC, TIC, TOC, DOC, NPOC, NPOCplus; optional TNb (CLD or ChD); optional POC (particulate organic carbon)
  • Oxidation Method:
    Catalytic high-temperature combustion up to 950°C (liquids); catalyst-free oxidation up to 1300°C (solids, duo models)
  • Measuring Range:
    0–30,000 mg/L C; TNb: 0–200 mg/L (CLD) or 0–100 mg/L (ChD); Solids: 0–100 wt-%
  • Detection Limit:
    4 µg/L C; TNb (CLD): 5 µg/L; TNb (ChD): 50 µg/L
  • Measuring Time:
    3–5 min/sample
multi N/C 2300
Analytik Jena
  • Measurement Mode(s):
    TC, TIC, TOC, DOC, NPOC, NPOCplus; optional TNb (CLD or ChD)
  • Oxidation Method:
    Catalytic high-temperature combustion up to 950°C; optional catalyst-free oxidation up to 1300°C (solids with HT 1300 module)
  • Measuring Range:
    0–30,000 mg/L C; TNb: 0–200 mg/L (CLD) or 0–100 mg/L (ChD)
  • Detection Limit:
    50 µg/L C; TNb (CLD): 5 µg/L; TNb (ChD): 50 µg/L
  • Measuring Time:
    3–5 min/sample
soli TOC&#174; cube TOC Analyzer
Elementar Americas
  • Measurement Mode(s):
    TOC, TOC400, TIC, TIC900, TC, ROC, TN
  • Oxidation Method:
    Inquire
  • Measuring Range:
    Inquire
  • Detection Limit:
    Inquire
  • Measuring Time:
    Inquire
TOC-200 Series Automatic TOC Analyzer
Toray Engineering
  • Measurement Mode(s):
    Online TOC, Offline TOC
  • Oxidation Method:
    Low-temperature sealed combustion at 650°C (NDIR detection)
  • Measuring Range:
    0–5 to 1,000 mg/L; optional 0–150 to 3,000 mg/L
  • Detection Limit:
    Inquire
  • Measuring Time:
    4 min (TC); 5 min (TOC)
TOC-250L Desktop TOC Analyzer
Toray Engineering
  • Measurement Mode(s):
    TC, NPOC, IC
  • Oxidation Method:
    Sealed combustion (low-temperature catalytic)
  • Measuring Range:
    0–2 to 2,000 mgC/L (TC, NPOC, IC); up to 40,000 mgC/L by dilution
  • Detection Limit:
    <0.05 mgC/L (standard); <0.02 mgC/L (high sensitivity)
  • Measuring Time:
    ~4.5 min (excluding preprocessing and cleaning)
CA72TOC High Temperature TOC Analyzer
Endress+Hauser
  • Measurement Mode(s):
    TOC (continuous online)
  • Oxidation Method:
    High-temperature catalytic combustion
  • Measuring Range:
    0.25–600 mg TOC/L (standard); up to 12,000 mg/L with pre-dilution
  • Detection Limit:
    Inquire
  • Measuring Time:
    Inquire
TOC-210 Series Automatic TOC Analyzer
Toray Engineering
  • Measurement Mode(s):
    Online TOC, process monitoring, discharge monitoring
  • Oxidation Method:
    Low-temperature sealed combustion at 650°C (optional high-sensitivity NDIR)
  • Measuring Range:
    0–100 mg/L (low-range, high sensitivity option); wider ranges available
  • Detection Limit:
    Inquire
  • Measuring Time:
    Inquire
XPERT TOC/TNb
TE Instruments
  • Measurement Mode(s):
    TOC, TNb (Total Bound Nitrogen); configurable as TOC-only or TNb-only
  • Oxidation Method:
    High-temperature combustion with catalyst
  • Measuring Range:
    Low ppb to high ppm (wide dynamic range, switchable in single run)
  • Detection Limit:
    Inquire
  • Measuring Time:
    Inquire
CA78 Low-Range Online TOC Analyzer
Endress+Hauser
  • Measurement Mode(s):
    TOC (continuous online)
  • Oxidation Method:
    UV digestion with differential conductivity detection
  • Measuring Range:
    0.5–1,000 µg/L (ppb)
  • Detection Limit:
    0.5 µg/L (ppb)
  • Measuring Time:
    t90 = 50 s
FORMACS HT-i TOC/TN Analyzer
Skalar Analytical
  • Measurement Mode(s):
    TOC, TN; optional NO3+NO2 and TKN
  • Oxidation Method:
    High-temperature catalytic combustion
  • Measuring Range:
    Low ppb to high ppm
  • Detection Limit:
    Inquire
  • Measuring Time:
    Inquire
FORMACS HT TOC/TN Analyzer
Skalar Analytical
  • Measurement Mode(s):
    TC, IC, TOC, NPOC, POC, DOC; optional TN and NO3+NO2
  • Oxidation Method:
    High-temperature catalytic combustion
  • Measuring Range:
    Low ppb to high ppm
  • Detection Limit:
    Inquire
  • Measuring Time:
    Inquire
CA79 Low-Range TOC Analyzer for Life Sciences
Endress+Hauser
  • Measurement Mode(s):
    TOC (continuous online)
  • Oxidation Method:
    UV digestion with differential conductivity detection
  • Measuring Range:
    0.5–1,000 µg/L (ppb)
  • Detection Limit:
    Inquire
  • Measuring Time:
    t90 = 50 s
LAR QuickTOCeco Industrial TOC Water Analyzer
LAR Process Analysers
  • Measurement Mode(s):
    TC, TOC (TRUE TOC), NPOC; COD/BOD by correlation
  • Oxidation Method:
    High-temperature combustion (1,200°C), NDIR detection
  • Measuring Range:
    1–10,000 ppm TOC (further options available)
  • Detection Limit:
    Inquire
  • Measuring Time:
    TC: < 2 min; TOC: < 3–4 min
Select up to 5 products from above to compare or request more information.
Showing 40 of 48 products

Tags:

Please Login or Register to Create Tags
  • <<
  • >>
  • Analytik Jena
  • Beckman Coulter Life Sciences
  • Elementar Americas
  • ELTRA
  • Endress+Hauser
  • Hach Company
  • LAR Process Analysers
  • Mettler Toledo
  • OI Analytical
  • Shimadzu
  • Skalar Analytical
  • TE Instruments
  • Teledyne LABS
  • Toray Engineering
  • Veolia Water Technologies

Review Laboratory Products

Review the laboratory equipment you use and receive an Amazon gift card!

Submit a Review
Get the Latest Updates, Technology News and Trends, New Products, Promotions, Buying Tips, and More!

Note: Labcompare disclaims any information on this site.