Total Organic Carbon Analyzer (TOC Analyzers)

Total Organic Carbon Analyzer (TOC Analyzers) A total organic carbon analyzer (also referred to as TOC analyzers) measures the amount of total organic carbon present in a liquid or water sample. TOC detection is important because of the effects that TOCs may have on health, not to mention the environmental effects and implications for the pharmaceutical manufacturing processes. Since all total organic carbon analyzers only measure total carbon, a TOC analyzer always requires some accounting for the inorganic carbon (IC) that is always present. TOC analyzers, including a portable TOC analyzer, utilize the same basic technique where acid is added to the liquid sample to remove IC. At this point, the IC is converted into carbon dioxide gas. It is then stripped out of the liquid by a carrier gas where the remaining inorganic carbon-free sample is then oxidized and the carbon dioxide generated from the oxidation process is directly related to the TOC total organic carbon in the sample. There are several methods for introducing the sample to TOC analyzers, including using a syringe, autosampler, and loop sampling. An important specification for total organic carbon analyzers is the measuring range. Carrier gas flow rate, average analysis time and process temperature are important as well for total organic carbon analysis.

Find, compare, and request a quote for total organic carbon analyzers (TOC analyzers) across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

Showing 8 of 48 products
Get Quote for All
Select up to 5 products from below to compare or request more information.
FORMACS HT-i TOC/TN Analyzer
Skalar Analytical
  • Measurement Mode(s):
    TOC, TN; optional NO3+NO2 and TKN
  • Oxidation Method:
    High-temperature catalytic combustion
  • Measuring Range:
    Low ppb to high ppm
  • Detection Limit:
    Inquire
  • Measuring Time:
    Inquire
PRIMACS SNC-100 TOC/TN Analyzer
Skalar Analytical
  • Measurement Mode(s):
    TOC, TC, TIC, TEC (elemental carbon), TN/Protein
  • Oxidation Method:
    High-temperature combustion with NDIR detection (carbon); Dumas methodology with TCD detection (nitrogen)
  • Measuring Range:
    500 µg to 40 mg absolute carbon
  • Detection Limit:
    Inquire
  • Measuring Time:
    Inquire
XPERT TOC/TNb
TE Instruments
  • Measurement Mode(s):
    TOC, TNb (Total Bound Nitrogen); configurable as TOC-only or TNb-only
  • Oxidation Method:
    High-temperature combustion with catalyst
  • Measuring Range:
    Low ppb to high ppm (wide dynamic range, switchable in single run)
  • Detection Limit:
    Inquire
  • Measuring Time:
    Inquire
Lotix TOC Combustion Analyzer
Teledyne LABS
  • Measurement Mode(s):
    Inquire
  • Oxidation Method:
    High Temperature Combustion (680°C-1000°C)
  • Measuring Range:
    Inquire
  • Detection Limit:
    0.5 ppb C
  • Measuring Time:
    Inquire
TOC-200 Series Automatic TOC Analyzer
Toray Engineering
  • Measurement Mode(s):
    Online TOC, Offline TOC
  • Oxidation Method:
    Low-temperature sealed combustion at 650°C (NDIR detection)
  • Measuring Range:
    0–5 to 1,000 mg/L; optional 0–150 to 3,000 mg/L
  • Detection Limit:
    Inquire
  • Measuring Time:
    4 min (TC); 5 min (TOC)
TOC-210 Series Automatic TOC Analyzer
Toray Engineering
  • Measurement Mode(s):
    Online TOC, process monitoring, discharge monitoring
  • Oxidation Method:
    Low-temperature sealed combustion at 650°C (optional high-sensitivity NDIR)
  • Measuring Range:
    0–100 mg/L (low-range, high sensitivity option); wider ranges available
  • Detection Limit:
    Inquire
  • Measuring Time:
    Inquire
TOC-250L Desktop TOC Analyzer
Toray Engineering
  • Measurement Mode(s):
    TC, NPOC, IC
  • Oxidation Method:
    Sealed combustion (low-temperature catalytic)
  • Measuring Range:
    0–2 to 2,000 mgC/L (TC, NPOC, IC); up to 40,000 mgC/L by dilution
  • Detection Limit:
    <0.05 mgC/L (standard); <0.02 mgC/L (high sensitivity)
  • Measuring Time:
    ~4.5 min (excluding preprocessing and cleaning)
Sievers M9e TOC Analyzer
Veolia Water Technologies
  • Measurement Mode(s):
    Online, laboratory, and portable configurations; Standard and Turbo modes
  • Oxidation Method:
    UV/persulfate oxidation with membrane conductometric detection
  • Measuring Range:
    0.03 ppb to 50 ppm (Standard); 0.20 ppb to 10 ppm (Turbo)
  • Detection Limit:
    0.03 ppb (Standard mode)
  • Measuring Time:
    2 minutes (Standard); 4 seconds (Turbo)
Select up to 5 products from above to compare or request more information.
Showing 8 of 48 products

Tags:

Please Login or Register to Create Tags
  • <<
  • >>
  • Analytik Jena
  • Beckman Coulter Life Sciences
  • Elementar Americas
  • ELTRA
  • Endress+Hauser
  • Hach Company
  • LAR Process Analysers
  • Mettler Toledo
  • OI Analytical
  • Shimadzu
  • Skalar Analytical
  • TE Instruments
  • Teledyne LABS
  • Toray Engineering
  • Veolia Water Technologies

Review Laboratory Products

Review the laboratory equipment you use and receive an Amazon gift card!

Submit a Review