Particle imaging systems use rapid digital imaging and software to determine both the sizes and shapes of particles in a material. Particle shape analysis is used in the manufacturing and testing of chemicals, pharmaceuticals and food products as well as in materials science industry. Particle imaging systems record pictures of particles in dry or wet samples, then calculate the diameter, volume or more complex parameters based on the information needed.
Static particle imaging systems analyze mounted, stationary samples and offer high resolution of small particles. In dynamic particle imaging systems, particles flow by the camera (similar to a microscope) and larger sample sizes can by analyzed. Particle size limits and analysis times vary by instrument; particle imaging systems can measure sizes ranging from 0.5 um to 30 mm and particle shape analysis takes 30 seconds to 3 minutes per sample.
Find, compare, and request a quote for particle imaging systems across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
|  |  |  |
| Company | Malvern Panalytical | Malvern Panalytical | Malvern Panalytical |
| Item | Morphologi 4 Particle Characterization System | Hydro Insight Dynamic Particle Imaging Systsem | Morphologi 4-ID Morphologically-Directed Raman Spectroscopy System |
| Citations | | | |
| Figures | | | |
| Catalog Number | Morphologi 4 | Hydro Insight | Morphologi 4-ID |
| Price | | | |
| Description | Rapid, automated particle size and particle shape analysis
Morphologi 4 provides detailed morphological descriptions of particulate samples through static image analysis, enabling a greater understanding of both sample and process. It can equally be used as an R&D tool to investigate challenging Rapid, automated particle size and particle shape analysis
Morphologi 4 provides detailed morphological descriptions of particulate samples through static image analysis, enabling a greater understanding of both sample and process. It can equally be used as an R&D tool to investigate challenging applications and in automated QC analysis where generation of robust, user-independent results and validation are required.
Features: - Broad particle size range, from 0.5 µm to over >1300 µm, enables size measurements of a wide range of samples
- 20+ morphological parameters deliver a highly-detailed description for deeper understanding of your particulate material
- SOP control, from sample dispersion to data analysis, provides simple and automated operation for robust, repeatable measurements
- Automated ‘Sharp Edge’ analysis enables detection of even low contrast particles
- Advanced manual microscope mode and ability to return to particles of interest enables an even closer examination of unexpected particles
- High resolution microscope ensures quality particle images for optimum image analysis data
- Integrated dry powder dispersion unit delivers reproducible sample dispersion, critical to achieving meaningful results
- Dedicated sample presentation accessories enable measurement of a wide variety of sample types, including suspensions and filters
- Advanced data exploration tools generate maximum sample knowledge
- 21 CFR Part 11 software option ensures regulatory compliance
... Read More | The Hydro Insight is designed to work alongside the Mastersizer 3000, providing particle images and particle shape data to complement the particle size data from laser diffraction.
- High-speed, high-resolution dynamic imaging technology: 127-frames-per-second digital camera with up to 5 megapixel
The Hydro Insight is designed to work alongside the Mastersizer 3000, providing particle images and particle shape data to complement the particle size data from laser diffraction.
- High-speed, high-resolution dynamic imaging technology: 127-frames-per-second digital camera with up to 5 megapixel resolution
- Imaging of individual particles and liquid particle dispersions
- Thumbnail images saved for post-run viewing
- Quantitative data on particle size and shape, including particle width and elongation data
... Read More | Rapid, automated, component-specific particle characterization in a single, integrated platform
Morphologi 4-ID delivers detailed component-specific morphological descriptions of particulate blends through Morphologically-Directed Raman Spectroscopy (MDRS). This combines automated particle imagingRapid, automated, component-specific particle characterization in a single, integrated platform
Morphologi 4-ID delivers detailed component-specific morphological descriptions of particulate blends through Morphologically-Directed Raman Spectroscopy (MDRS). This combines automated particle imaging with Raman spectroscopy in a single, integrated platform, providing the power to unlock complex particle characterization problems.
Features: - Patented MDRS capability delivers representative component-specific particle size and shape data, delivering full characterization of your sample
- All the functionality of the Morphologi 4 combined with a dedicated Raman platform for both physical and chemical particle characterization in a single, automated measurement
- Automatically measures Raman spectra for hundreds or thousands of particles, saving valuable analyst time
- Intuitive software ensures suitability for experienced and non-experienced spectroscopists alike
- Easy correlation of morphological properties with chemical information provides the most comprehensive understanding of your sample
- 21 CFR Part 11 software option ensures regulatory compliance
- Adaptable workflows enable methods to be tailored to specific user or application requirements. Select particles for chemical analysis:
- manually, from particle images
- morphologically-directed, based on user-specified classifications (MDRS)
- automatically and objectively by the software
- Ability to export spectra in industry-standard format supports unknown component identification using 3rd party spectral libraries
- Tight control of laser power and acquisition time enables measurement optimization for a wide range of materials, from weak Raman scatterers to those that are thermally sensitive
... Read More |
| Particle Size | 0.5 µm to 1300 µm | 1 to 300µm with standard lens, 10 to 800µm with low magnification lens | 0.5 µm to 1300 µm |
| Sample Type | Wide variety of sample types, including suspensions and filters. | Particles dispersed by the Mastersizer 3000’s wet accessories | Wide variety of sample types |
| Applications | Pharmaceutical development, Spray drying, Energy storage/Batteries, Powder metallurgy, Mining and minerals. | Provides an extraordinary view of your samples in dispersion, individual particle images, and quantitative particle shape data. | Building materials, Energy storage/batteries, Forensics |
| Get Quote | | | |