
A gas chromatograph separates volatile gaseous compounds carried by an inert gas such as helium, nitrogen, argon or hydrogen across a solid stationary phase. Components in a gas chromatograph include a sample injector, flow controller, GC column, column oven, a detector, and a computer for data acquisition and analysis. A combination of electronic sensors and pumps maintain either a constant or variable mobile phase flow rate from 0.001 to 100 mL per minute. GC instruments typically have a maximum temperature of 350C to 450C.
Gas Chromatographs can be equipped with several types of detectors including: a flame ionization detector (FID), a thermal conductivity detector (TCD), a flame photometric detector (FPD), an electron capture detector (ECD), and even a mass spectrometer, for example. Gas chromatography is a powerful standalone application used in many industries, especially environmental testing. However, GC instruments are also found in combination with mass spectrometers, refining the GC separation with additional mass analysis. Fast run times and robust data acquisition and analysis software are important features in a gas chromatograph.
Find, compare, and request a quote for GC systems across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
Your search for Gas chromatography returned 4 results.
Get Quote for All
Select up to 5 products from below to compare or request more information.
LECO
- FID, ECD, SCD
- Inquire
- 1 inlet
Shimadzu
- GCMS, FID, FPD, TCD, ECD, FTD
- [RT + 4C] to 350C
- Inquire
Shimadzu
- Quadrupole mass spectrometer
- Inquire
- Inquire
Thermo Fisher Scientific
- Up to 2: FID, TCD, ECD, NPD, FPD, PDD
- Ambient +3°C to 450°C (cryogenic option for sub-ambient operation)
- Inquire
Other GC System Products
SCION Instruments
- Electron multiplier with ±5 kV post acceleration and with on-the-fly multiplier gain optimization for Extended Dynamic Range (EDR™); direct ion collection onto multiplier for negative ion detection without dynode loss.
- GC Oven Temperature: Ambient +4 °C – 450 °C
Source Temperature: 100 – 350 °C
- Inquire
Inquire
Shimadzu
- FID, FPD, ECD
- (room temperature + 4 °C) to 450 °C
- Split/Splitless Injection Unit
Agilent Technologies
- 1 detector; premium MDLs
- Ambient +4 °C to 450 °C
- 1 inlet
Ellutia
- FID, TCD, ECD, FPD, TEA (single detector per instrument)
- Inquire
- Split/splitless injector, optional on-column injection
Ellutia
- FID, ECD, TEA (single detector per instrument)
- Ambient +20C to 600C
- Temperature-programmable split/splitless injector (ambient +20 °C to 600 °C, up to 720 °C/min ramp rate, 10 programmable ramps)
Falcon Analytical
- FID (micro Flame Ionization Detector) and TCD (micro Thermal Conductivity Detector, constant temperature filament)
- 0 °C to 35 °C (operating); max detector temperature 350 °C
- Heated split/splitless injection port with septum purge, 350 °C max
SCION Instruments
- EDR™ Electron multiplier with ±5 kV post acceleration and with on-the-fly multiplier gain optimization for Extended Dynamic Range (EDR); direct ion collection onto multiplier for negative ion detection without dynode loss for 6 orders dynamic range.
- Source Temperature: 100 – 350 °C.
- Inquire
Inquire
SCION Instruments
- Up to 2 detectors
- Column oven from 4°C to 450°C, cooling to -100°C optional
- 2 injection ports
Inquire
SCION Instruments
- Up to 4 detectors (including MS)
- Large capacity column oven from 4°C to 450°C, cooling to -100°C optional
- Up to 3 injection ports
Inquire
Shimadzu
- FID, FPD, BID, ECD, TCD, FTD/NPD)
- (ambient +2 °C) to 450 °C
- Up to 3
Shimadzu
- FID, TCD, BID, ECD, FPD, FTD (up to 4)
- Ambient +2°C to 450°C
- Split/Splitless, Direct, OCI, Packed, MMI (Multi-Mode Injector), SPI — up to 3 simultaneous
Thermo Fisher Scientific
- Thermal Conductivity Detector, IRMS
- Inquire
- Inquire
Lucidity Systems
- Flame Ionization Detector (FID)
- Up to 400°C
- Split/Splitless injection port (2-zone programmable temperatures)
Inquire
PerkinElmer
- Flame Ionization Detector (FID), Electron Capture Detector (ECD), Single Quadrupole Mass Spectrometer (MS 2400 SQ)
- Inquire
Inquire
SRI Instruments
- Up to 4 detectors simultaneously (TCD, FID, FPD, ECD, PID, HID, etc.)
- Ambient to 400°C (programmable)
- Single injector: On-column, Heated Flash Vaporization, Split/Splitless, or PTV
Inquire
SRI Instruments
- Up to 4 detectors simultaneously; choice of 16 detector types including FID, TCD, FPD, ECD, PID, and more
- Ambient to 400°C
- On-column, Heated Flash Vaporization, Split/Splitless, or PTV injector
Inquire
SRI Instruments
- Up to 6 simultaneously, choice of 16 detector types
- Inquire
- Inquire
Inquire
SRI Instruments
- TCD (Thermal Conductivity Detector), FID (Flame Ionization Detector) with Methanizer
- Ambient to 400C
- Two 10-port gas sampling valves
Inquire
Select up to 5 products from above to compare or request more information.
Tags:
Please Login or Register to Create Tags