LC MS Instrument

LC MS Instrument Comprising two components, a liquid-phase separation system and a mass spectrometer, liquid chromatograph mass spectrometers (LC MS instruments) couple sample fractionation and analysis. The separation can be accomplished via standard liquid chromatography, HPLC, UPLC, or even nano-LC. Any liquid-phase separation will do, so long as its output can be directed into the mass analyzer (for instance, via an electrospray ionization source). The mass spectrometer is similarly flexible, ranging from the simplest single quadrupole to a Fourier transform ion cyclotron resonance instrument. Just remember, in a liquid chromatograph mass spectrometer the column flow is continuous, meaning the mass analyzer must be fast enough to thoroughly analyze one peak before the next one comes off the column. And, unlike with MALDI MS, once a peak is analyzed, it’s gone.

Showing 27 of 27 products
  • <<
  • >>
Get Quote for All
Select up to 5 products from below to compare or request more information.
VERITY 271 LCMS System
Gilson Inc
  • Ionization Method(s):
    Inquire
  • Mass Analyzer:
    Inquire
  • Scanning Speed:
    Inquire
  • Resolution:
    Inquire
VERITY 281 LCMS System
Gilson Inc
  • Ionization Method(s):
    Inquire
  • Mass Analyzer:
    Inquire
  • Scanning Speed:
    Inquire
  • Resolution:
    Inquire
AccuTOF LC-Express Time-of-Flight Mass Spectrometer
JEOL USA, Inc.
  • Ionization Method(s):
    ESI, DART, and CSI (ColdSpray) are supported
  • Mass Analyzer:
    Time-of-Flight
  • Scanning Speed:
    Up to 16,000 spectra/second
  • Resolution:
    Greater than 6,000 FWHM (Full Width at Half Maximum)
Echo® MS+ system
SCIEX
  • Ionization Method(s):
    Electrospray Ionization
  • Mass Analyzer:
    Triple Quad or TOF
  • Scanning Speed:
    Up to 3 samples per second
  • Resolution:
    Inquire
Citations:
(7)
Intabio ZT system
SCIEX
  • Ionization Method(s):
    icIEF
  • Mass Analyzer:
    Time of Flight
  • Scanning Speed:
    Inquire
  • Resolution:
    Inquire
SCIEX 7500+ System
SCIEX
  • Ionization Method(s):
    OptiFlow® Pro Ion Source
  • Mass Analyzer:
    Triple quadrupole
  • Scanning Speed:
    20,000 Da/s
  • Resolution:
    Up to 3100 for mass 922 in LIT mode 1000 Da/s (0.3 Da)
    Tune to a peak width of 0.5 Da for TQ mode
Citations:
(1)
X500R QTOF system
SCIEX
  • Ionization Method(s):
    Turbo V ion source with twin sprayer ESI probe
    and twin sprayer APCI probe
  • Mass Analyzer:
    QTOF
  • Scanning Speed:
    Up to 25 Hz (25 spectra per second)
  • Resolution:
    Equal to or greater than 42,000 (FWHM) measured on the (M+6H)6+ charge isotope cluster for bovine insulin at m/z 956
Citations:
(114)
ZenoTOF 7600 system
SCIEX
  • Ionization Method(s):
    APCI and ESI modes
  • Mass Analyzer:
    TOF
  • Scanning Speed:
    up to 25 Hz (25 spectra per second)
  • Resolution:
    Equal to or greater than 42,000 (FWHM) measured on the [M+6H]6+ charge isotope cluster for bovine insulin at m/z 956
Citations:
(11)
LCMS-2020 Single Quadrupole Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    ESI, APCI, Dual Ionization
  • Mass Analyzer:
    Single Quadrupole
  • Scanning Speed:
    15,000 u/sec
  • Resolution:
    R = 2 M
Citations:
(919)
Figures:
(1)
LCMS-2050 Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    ESI, APCI, Dual Ionization
  • Mass Analyzer:
    Single Quadrupole
  • Scanning Speed:
    15,000 u/sec
  • Resolution:
    Inquire
LCMS-8050RX Triple Quadrupole LC/MS/MS Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    ESI, APCI, Dual Ionization, Micro-ESI
  • Mass Analyzer:
    Q1 & Q3 are molybdenum hyperbolic mass filters with pre-rods; Q1 includes post-rods
  • Scanning Speed:
    30,000 u/sec
  • Resolution:
    R < 0.7 u FWHM
Citations:
(597)
Figures:
(2)
LCMS-8060RX Triple Quadrupole LC/MS/MS Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    ESI, APCI, Dual Ionization, Micro-ESI
  • Mass Analyzer:
    Q1 & Q3 are molybdenum hyperbolic mass filters with pre-rods; Q1 includes post-rods
  • Scanning Speed:
    Max. 30,000 u/sec (in all scan modes) (0.1 u step: 300,000 data points/sec)
  • Resolution:
    R < 0.7 u FWHM and adjustable to 0.5 u
Citations:
(15)
LCMS-8065XE Triple Quadrupole LC/MS/MS Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    ESI, APCI (optional)
  • Mass Analyzer:
    Q1 & Q3 are molybdenum hyperbolic mass filters with pre-rods; Q1 includes post-rods
  • Scanning Speed:
    Max. 30,000 u/sec (in all scan modes)
  • Resolution:
    R < 0.7 u FWHM and adjustable to 0.5 u
LCMS-TQ RX Series Triple Quadrupole LC-MS/MS
Shimadzu
  • Ionization Method(s):
    ESI, APCI, Dual Ionization, Micro-ESI
  • Mass Analyzer:
    Q1 & Q3 are molybdenum hyperbolic mass filters with pre-rods; Q1 includes post-rods
  • Scanning Speed:
    Max. 30,000 u/sec (in all scan modes) (0.1 u step: 300,000 data points/sec)
  • Resolution:
    R < 0.7 u FWHM and adjustable to 0.5 u
Nexera Mikros Microflow Liquid Chromatography Mass Spectrometer System
Shimadzu
  • Ionization Method(s):
    Micro-ESI
  • Mass Analyzer:
    Q1 & Q3 are molybdenum hyperbolic mass filters with pre-rods; Q1 includes post-rods
  • Scanning Speed:
    Inquire
  • Resolution:
    Inquire
Citations:
(9)
Nexera QX Multiplex LC-MS
Shimadzu
  • Ionization Method(s):
    ESI, APCI, Dual Ionization
  • Mass Analyzer:
    Q1 & Q3 are molybdenum hyperbolic mass filters with pre-rods; Q1 includes post-rods
  • Scanning Speed:
    Inquire
  • Resolution:
    Inquire
Orbitrap Eclipse™ Tribrid™ Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    Inquire
  • Mass Analyzer:
    Orbitrap
  • Scanning Speed:
    OTMSn up to 40 Hz ITMSn up to 45 Hz
  • Resolution:
    7500 to 500,000 (FWHM) at m/z 200
Orbitrap Exploris™ 240 Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    ESI and HRAM
  • Mass Analyzer:
    Orbitrap
  • Scanning Speed:
    Up to 22 Hz at resolution setting of 15,000 at m/z 200
  • Resolution:
    Up to 240,000 at m/z 200
Orbitrap Exploris™ 480 Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    ESI and HRAM
  • Mass Analyzer:
    Orbitrap
  • Scanning Speed:
    Up to 40 Hz at resolution setting of 7500 at m/z 200
  • Resolution:
    480,000 at m/z 195
Orbitrap Fusion™ Lumos™ Tribrid™ Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    HESI
  • Mass Analyzer:
    Orbitrap
  • Scanning Speed:
    Inquire
  • Resolution:
    7500-500,000 (FWHM) at m/z 200
Citations:
(35)
Orbitrap IQ-X™ Tribrid™ Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    ESI
  • Mass Analyzer:
    Orbitrap
  • Scanning Speed:
    Inquire
  • Resolution:
    7500 to 500,000 (FWHM) at m/z 200
Q Exactive™ UHMR Hybrid Quadrupole-Orbitrap™ Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    Inquire
  • Mass Analyzer:
    UHMR Hybrid Quadrupole-Orbitrap™
  • Scanning Speed:
    up to 12 Hz at resolution setting of 12,500 at m/z 400
  • Resolution:
    200,000 at m/z 400
Citations:
(17)
Thermo Scientific™ Tox Explorer™ Collection for Orbitrap™ Exploris™ 120 MS
Thermo Fisher Scientific
  • Ionization Method(s):
    Inquire
  • Mass Analyzer:
    Inquire
  • Scanning Speed:
    Up to 22 Hz
  • Resolution:
    Up to 120,000 (FWHM) at m/z 200, demonstrates outstanding resolving power, according to a product page
Tox Explorer™ Collection for Quantis™ Plus MS
Thermo Fisher Scientific
  • Ionization Method(s):
    Inquire
  • Mass Analyzer:
    Inquire
  • Scanning Speed:
    Inquire
  • Resolution:
    Inquire
BioAccord LC-MS System with ACQUITY Premier
Waters | Wyatt Technology
  • Ionization Method(s):
    Inquire
  • Mass Analyzer:
    Inquire
  • Scanning Speed:
    Inquire
  • Resolution:
    Inquire
QSight 500 LC/MS/MS System
PerkinElmer
  • Ionization Method(s):
    ESI, APCI
  • Mass Analyzer:
    Triple Quadrupole
  • Scanning Speed:
    Inquire
  • Resolution:
    Inquire
Inquire
Orbitrap Exploris™ 120 Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    ESI and HRAM
  • Mass Analyzer:
    Orbitrap
  • Scanning Speed:
    Up to 22 Hz at resolution setting of 15,000 at m/z 200
  • Resolution:
    Up to 120,000 at m/z 200
Select up to 5 products from above to compare or request more information.

Tags:

Please Login or Register to Create Tags

Articles

  • <<
  • >>
Shimadzu
LCMS-2020
4
1 Figure from 919 Publications
Shimadzu
LCMS-8050RX
2
2 Figures from 597 Publications
Showing 2 of 2 products
  • <<
  • >>
  • Gilson Inc
  • JEOL USA, Inc.
  • PerkinElmer
  • SCIEX
  • Shimadzu
  • Thermo Fisher Scientific
  • Waters | Wyatt Technology

Review Laboratory Products

Review the laboratory equipment you use and receive an Amazon gift card!

Submit a Review
Get the Latest Updates, Technology News and Trends, New Products, Promotions, Buying Tips, and More!

Note: Labcompare disclaims any information on this site.