LC MS Instrument

LC MS Instrument Comprising two components, a liquid-phase separation system and a mass spectrometer, liquid chromatograph mass spectrometers (LC MS instruments) couple sample fractionation and analysis. The separation can be accomplished via standard liquid chromatography, HPLC, UPLC, or even nano-LC. Any liquid-phase separation will do, so long as its output can be directed into the mass analyzer (for instance, via an electrospray ionization source). The mass spectrometer is similarly flexible, ranging from the simplest single quadrupole to a Fourier transform ion cyclotron resonance instrument. Just remember, in a liquid chromatograph mass spectrometer the column flow is continuous, meaning the mass analyzer must be fast enough to thoroughly analyze one peak before the next one comes off the column. And, unlike with MALDI MS, once a peak is analyzed, it’s gone.

Your search for LC/MS returned 38 results.
Showing 38 of 38 products
  • <<
  • >>
Get Quote for All
Select up to 5 products from below to compare or request more information.
LCMS-8060RX Triple Quadrupole LC/MS/MS Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    ESI, APCI, Dual Ionization, Micro-ESI
  • Mass Analyzer:
    Q1 & Q3 are molybdenum hyperbolic mass filters with pre-rods; Q1 includes post-rods
  • Scanning Speed:
    Max. 30,000 u/sec (in all scan modes) (0.1 u step: 300,000 data points/sec)
  • Resolution:
    R < 0.7 u FWHM and adjustable to 0.5 u
Citations:
(15)
SCIEX 7500+ System
SCIEX
  • Ionization Method(s):
    OptiFlow® Pro Ion Source
  • Mass Analyzer:
    Triple quadrupole
  • Scanning Speed:
    20,000 Da/s
  • Resolution:
    Up to 3100 for mass 922 in LIT mode 1000 Da/s (0.3 Da)
    Tune to a peak width of 0.5 Da for TQ mode
Citations:
(1)
Orbitrap Exploris&#8482; 240 Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    ESI and HRAM
  • Mass Analyzer:
    Orbitrap
  • Scanning Speed:
    Up to 22 Hz at resolution setting of 15,000 at m/z 200
  • Resolution:
    Up to 240,000 at m/z 200
Orbitrap Exploris&#8482; 480 Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    ESI and HRAM
  • Mass Analyzer:
    Orbitrap
  • Scanning Speed:
    Up to 40 Hz at resolution setting of 7500 at m/z 200
  • Resolution:
    480,000 at m/z 195
Q Exactive&#8482; UHMR Hybrid Quadrupole-Orbitrap&#8482; Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    Inquire
  • Mass Analyzer:
    UHMR Hybrid Quadrupole-Orbitrap™
  • Scanning Speed:
    up to 12 Hz at resolution setting of 12,500 at m/z 400
  • Resolution:
    200,000 at m/z 400
Citations:
(17)
Nexera QX Multiplex LC-MS
Shimadzu
  • Ionization Method(s):
    ESI, APCI, Dual Ionization
  • Mass Analyzer:
    Q1 & Q3 are molybdenum hyperbolic mass filters with pre-rods; Q1 includes post-rods
  • Scanning Speed:
    Inquire
  • Resolution:
    Inquire
Echo&#174; MS+ system
SCIEX
  • Ionization Method(s):
    Electrospray Ionization
  • Mass Analyzer:
    Triple Quad or TOF
  • Scanning Speed:
    Up to 3 samples per second
  • Resolution:
    Inquire
Citations:
(7)
LCMS-8050RX Triple Quadrupole LC/MS/MS Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    ESI, APCI, Dual Ionization, Micro-ESI
  • Mass Analyzer:
    Q1 & Q3 are molybdenum hyperbolic mass filters with pre-rods; Q1 includes post-rods
  • Scanning Speed:
    30,000 u/sec
  • Resolution:
    R < 0.7 u FWHM
Citations:
(597)
Figures:
(2)
ZenoTOF 7600 system
SCIEX
  • Ionization Method(s):
    APCI and ESI modes
  • Mass Analyzer:
    TOF
  • Scanning Speed:
    up to 25 Hz (25 spectra per second)
  • Resolution:
    Equal to or greater than 42,000 (FWHM) measured on the [M+6H]6+ charge isotope cluster for bovine insulin at m/z 956
Citations:
(11)
Orbitrap Eclipse&#8482; Tribrid&#8482; Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    Inquire
  • Mass Analyzer:
    Orbitrap
  • Scanning Speed:
    OTMSn up to 40 Hz ITMSn up to 45 Hz
  • Resolution:
    7500 to 500,000 (FWHM) at m/z 200
Orbitrap Fusion&#8482; Lumos&#8482; Tribrid&#8482; Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    HESI
  • Mass Analyzer:
    Orbitrap
  • Scanning Speed:
    Inquire
  • Resolution:
    7500-500,000 (FWHM) at m/z 200
Citations:
(35)
LCMS-8045RX Triple Quadrupole LC/MS/MS Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    ESI, APCI
  • Mass Analyzer:
    Triple Quadrupole
  • Scanning Speed:
    Up to 15,000 Da/s
  • Resolution:
    0.1 Da (unit resolution)
X500R QTOF system
SCIEX
  • Ionization Method(s):
    Turbo V ion source with twin sprayer ESI probe
    and twin sprayer APCI probe
  • Mass Analyzer:
    QTOF
  • Scanning Speed:
    Up to 25 Hz (25 spectra per second)
  • Resolution:
    Equal to or greater than 42,000 (FWHM) measured on the (M+6H)6+ charge isotope cluster for bovine insulin at m/z 956
Citations:
(114)
Orbitrap IQ-X&#8482; Tribrid&#8482; Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    ESI
  • Mass Analyzer:
    Orbitrap
  • Scanning Speed:
    Inquire
  • Resolution:
    7500 to 500,000 (FWHM) at m/z 200
BioAccord LC-MS System with ACQUITY Premier
Waters | Wyatt Technology
  • Ionization Method(s):
    Inquire
  • Mass Analyzer:
    Inquire
  • Scanning Speed:
    Inquire
  • Resolution:
    Inquire
LCMS-2020 Single Quadrupole Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    ESI, APCI, Dual Ionization
  • Mass Analyzer:
    Single Quadrupole
  • Scanning Speed:
    15,000 u/sec
  • Resolution:
    R = 2 M
Citations:
(919)
Figures:
(1)
LCMS-TQ RX Series Triple Quadrupole LC-MS/MS
Shimadzu
  • Ionization Method(s):
    ESI, APCI, Dual Ionization, Micro-ESI
  • Mass Analyzer:
    Q1 & Q3 are molybdenum hyperbolic mass filters with pre-rods; Q1 includes post-rods
  • Scanning Speed:
    Max. 30,000 u/sec (in all scan modes) (0.1 u step: 300,000 data points/sec)
  • Resolution:
    R < 0.7 u FWHM and adjustable to 0.5 u
Nexera Mikros Microflow Liquid Chromatography Mass Spectrometer System
Shimadzu
  • Ionization Method(s):
    Micro-ESI
  • Mass Analyzer:
    Q1 & Q3 are molybdenum hyperbolic mass filters with pre-rods; Q1 includes post-rods
  • Scanning Speed:
    Inquire
  • Resolution:
    Inquire
Citations:
(9)
LCMS-8065XE Triple Quadrupole LC/MS/MS Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    ESI, APCI (optional)
  • Mass Analyzer:
    Q1 & Q3 are molybdenum hyperbolic mass filters with pre-rods; Q1 includes post-rods
  • Scanning Speed:
    Max. 30,000 u/sec (in all scan modes)
  • Resolution:
    R < 0.7 u FWHM and adjustable to 0.5 u
6475 Triple Quadrupole LC/MS
Agilent Technologies
  • Ionization Method(s):
    ESI (Electrospray Ionization), AJS (Agilent Jet Stream), APCI, MultiMode (ESI+APCI), NanoESI
  • Mass Analyzer:
    Triple Quadrupole (QqQ)
  • Scanning Speed:
    500 MRM transitions/s; minimum MRM dwell time 0.5 ms
  • Resolution:
    Unit = 0.7 Da FWHM; Wide = 1.2 Da; Widest = 2.5 Da; Narrow = 0.4 Da (m/z 5 to 1,500)
Tox Explorer&#8482; Collection for Quantis&#8482; Plus MS
Thermo Fisher Scientific
  • Ionization Method(s):
    Inquire
  • Mass Analyzer:
    Inquire
  • Scanning Speed:
    Inquire
  • Resolution:
    Inquire
VERITY 271 LCMS System
Gilson Inc
  • Ionization Method(s):
    Inquire
  • Mass Analyzer:
    Inquire
  • Scanning Speed:
    Inquire
  • Resolution:
    Inquire
VERITY 281 LCMS System
Gilson Inc
  • Ionization Method(s):
    Inquire
  • Mass Analyzer:
    Inquire
  • Scanning Speed:
    Inquire
  • Resolution:
    Inquire
AccuTOF LC-Express Time-of-Flight Mass Spectrometer
JEOL USA, Inc.
  • Ionization Method(s):
    ESI, DART, and CSI (ColdSpray) are supported
  • Mass Analyzer:
    Time-of-Flight
  • Scanning Speed:
    Up to 16,000 spectra/second
  • Resolution:
    Greater than 6,000 FWHM (Full Width at Half Maximum)
Intabio ZT system
SCIEX
  • Ionization Method(s):
    icIEF
  • Mass Analyzer:
    Time of Flight
  • Scanning Speed:
    Inquire
  • Resolution:
    Inquire
Thermo Scientific&#8482; Tox Explorer&#8482; Collection for Orbitrap&#8482; Exploris&#8482; 120 MS
Thermo Fisher Scientific
  • Ionization Method(s):
    Inquire
  • Mass Analyzer:
    Inquire
  • Scanning Speed:
    Up to 22 Hz
  • Resolution:
    Up to 120,000 (FWHM) at m/z 200, demonstrates outstanding resolving power, according to a product page
TSQ Fortis Plus Triple Quadrupole Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    Electrospray Ionization (ESI), Atmospheric Pressure Chemical Ionization (APCI) via OptaMax NG ion source; VeriSpray PaperSpray
  • Mass Analyzer:
    Triple Quadrupole
  • Scanning Speed:
    600 SRMs/sec
  • Resolution:
    High-resolution selected reaction monitoring (H-SRM)
TSQ Quantis Plus Triple Quadrupole Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    ESI, APCI via OptaMax NG ion source; FAIMS Pro Duo interface; VeriSpray PaperSpray; EASY-Spray; Nanospray Flex Series
  • Mass Analyzer:
    Triple Quadrupole
  • Scanning Speed:
    800 SRMs/sec
  • Resolution:
    0.4 FWHM
LCMS-2050 Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    ESI, APCI, Dual Ionization
  • Mass Analyzer:
    Single Quadrupole
  • Scanning Speed:
    15,000 u/sec
  • Resolution:
    Inquire
LCMS-9030 Quadrupole Time-of-Flight Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    ESI, APCI
  • Mass Analyzer:
    Quadrupole Time-of-Flight (Q-TOF)
  • Scanning Speed:
    100 Hz maximum acquisition rate
  • Resolution:
    30,000 FWHM
TSQ Altis Plus Triple Quadrupole Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    Electrospray Ionization (ESI/HESI), Atmospheric Pressure Chemical Ionization (APCI) via OptaMax NG ion source; VeriSpray PaperSpray; FAIMS Pro Duo (optional)
  • Mass Analyzer:
    Triple Quadrupole (segmented quadrupoles with hyperbolic faces)
  • Scanning Speed:
    600 SRMs/second
  • Resolution:
    0.2 FWHM (high-resolution SRM)
InfinityLab Pro iQ Plus LC/MS
Agilent Technologies
  • Ionization Method(s):
    ESI (Electrospray Ionization), AJS (Agilent Jet Stream), APCI (Atmospheric Pressure Chemical Ionization), MMI (MultiMode ESI+APCI) — Pro iQ Plus includes AJS
  • Mass Analyzer:
    Single Quadrupole
  • Scanning Speed:
    15,000 Da/s
  • Resolution:
    Inquire
Citrine System
SCIEX
  • Ionization Method(s):
    Electrospray Ionization (ESI) and Atmospheric Pressure Chemical Ionization (APCI)
  • Mass Analyzer:
    Triple Quadrupole / QTRAP Hybrid (linear ion trap + triple quadrupole)
  • Scanning Speed:
    1 ms MRM dwell times; 5 ms polarity switching
  • Resolution:
    Inquire
Orbitrap Exploris&#8482; 120 Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    ESI and HRAM
  • Mass Analyzer:
    Orbitrap
  • Scanning Speed:
    Up to 22 Hz at resolution setting of 15,000 at m/z 200
  • Resolution:
    Up to 120,000 at m/z 200
Orbitrap Astral Zoom Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    ESI (HESI), APCI (optional), nano-ESI via OptiSpray, EASY-Spray, NanoSpray Flex NG; FAIMS Pro Duo interface (optional)
  • Mass Analyzer:
    Quadrupole, Orbitrap, and Astral analyzer (dual HRAM)
  • Scanning Speed:
    Astral analyzer MS2: up to 270 Hz; Orbitrap MS2: up to 40 Hz at resolution 7,500 at m/z 200
  • Resolution:
    Orbitrap: up to 480,000 FWHM at m/z 200; Astral: 80,000 FWHM at m/z 524 (or 100,000 FWHM at m/z 138 in TMT HR mode)
Orbitrap Excedion Pro Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    ESI, APCI via OptaMax Plus ion source; nano-ESI via OptiSpray, EASY-Spray, NanoSpray Flex NG; EASY-ETD (optional); FAIMS Pro Duo interface (optional)
  • Mass Analyzer:
    Quadrupole-Orbitrap hybrid (ultra-high-field Orbitrap mass analyzer, 4 kV central electrode voltage)
  • Scanning Speed:
    Up to 70 Hz MS and MS/MS in the Orbitrap mass analyzer
  • Resolution:
    Up to 480,000 FWHM at m/z 200
Orbitrap Exploris EFOX Mass Detector
Thermo Fisher Scientific
  • Ionization Method(s):
    Heated electrospray ionization (HESI-II) via OptaMax NG ion source; flow rates 1–1,000 µL/min; EASY-IC internal calibrant source
  • Mass Analyzer:
    High-field Orbitrap (4 kV central electrode voltage)
  • Scanning Speed:
    Up to 22 Hz at resolution setting of 15,000
  • Resolution:
    Up to 90,000 FWHM at m/z 200
QSight 500 LC/MS/MS System
PerkinElmer
  • Ionization Method(s):
    ESI, APCI
  • Mass Analyzer:
    Triple Quadrupole
  • Scanning Speed:
    Inquire
  • Resolution:
    Inquire
Inquire
Select up to 5 products from above to compare or request more information.

Tags:

Please Login or Register to Create Tags

Articles

  • <<
  • >>
  • Agilent Technologies
  • Gilson Inc
  • JEOL USA, Inc.
  • PerkinElmer
  • SCIEX
  • Shimadzu
  • Thermo Fisher Scientific
  • Waters | Wyatt Technology