Inductively Coupled Plasma Mass Spectrometer (ICP MS)

Inductively Coupled Plasma Mass Spectrometer (ICP MS) Inductively coupled plasma mass spectrometers (ICP-MS) utilize inductively coupled plasma for sample ionization and an MS for ion separation and quantification. The low detection limits and high productivity possible with ICP-MS are particularly useful for trace metal analysis and environmental testing. Common components of an ICP-MS system include a sample introduction system, an ion source, a vacuum system, a collision reaction cell, ion optics, a mass spectrometer (often a quadrupole), and a detector. An analytical working range of nine orders of magnitude, detection limits below the ppt range, and aptitude for isotopic analysis are hallmarks of ICP-MS. ICP-MS instruments are commonly configured for routine analyses, high-matrix interference samples, or specific applications, such as work in the semiconductor industry or medical and forensic toxicology fields. Also, be sure to consider any desired customization options, such as chromatographic coupling or use with organic solvents.

Find, compare, and request a quote for inductively coupled plasma mass spectrometers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

Your search for ICP-QQQ returned 0 results.
Showing 27 of 27 products
  • <<
  • >>
Get Quote for All
Select up to 5 products from below to compare or request more information.

Other Inductively Coupled Plasma Mass Spectrometer (ICP MS) Products

7850 ICP-MS
Agilent Technologies
  • Mass Analyzer:
    Mass range: 2 to 260 u
    Resolution: Variable from 0.3 u to 1.0 u
  • Sensitivity:
    Inquire
  • Dynamic Range:
    Inquire
Citations:
(9)
7900 ICP-MS
Agilent Technologies
  • Mass Analyzer:
    Quadrupole; Mass range: 2 to 260 u; Resolution: Variable from 0.3 u to 1.0 u
  • Sensitivity:
    less than ppt
  • Dynamic Range:
    11 orders
Citations:
(410)
8900 Triple Quadrupole ICP-MS
Agilent Technologies
  • Mass Analyzer:
    Inquire
  • Sensitivity:
    Inquire
  • Dynamic Range:
    Inquire
Citations:
(21)
Agilent ICP-MS Automation Systems
Agilent Technologies
  • Mass Analyzer:
    Inquire
  • Sensitivity:
    Inquire
  • Dynamic Range:
    Inquire
PlasmaQuant® MS System
Analytik Jena
  • Mass Analyzer:
    Quadrupole
  • Sensitivity:
    Up to 1500 Mcps/ppm at <2 % CeO
  • Dynamic Range:
    11 orders linear analytical range, 0.1-1010 cps, all pulse counting mode
Citations:
(14)
OptiMass 9500 ICP-TOFMS
GBC Scientific Equipment
  • Mass Analyzer:
    Orthogonal acceleration Time-of-Flight (TOF); mass range 1–260 u; resolution 0.4 u (R =1200 at 238U); 30,000 full spectra/s
  • Sensitivity:
    Parts per trillion (ppt) detection limits; mass range 1–260 amu; >30,000 full spectra per second; resolution typically 1,200 or greater for 238U (0.4 amu)
  • Dynamic Range:
    Mass range 1 to 260 amu
OptiMass 9600 ICP-TOFMS
GBC Scientific Equipment
  • Mass Analyzer:
    Orthogonal acceleration Time-of-Flight (TOF) with Octopole Collision Cell (OCC); mass range 1–260 u; resolution 0.4 u (R =1200 at 238U); 30,000 full spectra/s
  • Sensitivity:
    Parts per trillion (ppt) detection limits; mass range 1–260 amu; >30,000 full spectra per second; resolution typically 1,200 or greater for 238U (0.4 amu)
  • Dynamic Range:
    Mass range 1 to 260 amu
NexION 1100 ICP-MS
PerkinElmer
  • Mass Analyzer:
    Three-quadrupole design (Q0 ion deflector, Q1 universal cell, Q2 analyzer); mass range 2–260 u; resolution <0.7 u; 34 MHz free-running RF generator
  • Sensitivity:
    Inquire
  • Dynamic Range:
    =14 orders of magnitude (EDR, 10¹4)
Inquire
NexION 2200 ICP-MS
PerkinElmer
  • Mass Analyzer:
    Three-quadrupole design (Q0 ion deflector, Q1 universal cell with dynamic bandpass tuning, Q2 analyzer); mass range 2–260 u; resolution <0.7 u; 34 MHz free-running RF generator
  • Sensitivity:
    Inquire
  • Dynamic Range:
    =14 orders of magnitude (EDR, 10¹4)
Inquire
ICPMS-2030 Inductively Coupled Plasma Mass Spectrometer
Shimadzu
  • Mass Analyzer:
    Quadrupole
  • Sensitivity:
    Inquire
  • Dynamic Range:
    109
Citations:
(39)
ICPMS-2040 / ICPMS-2050 Series
Shimadzu
  • Mass Analyzer:
    Quadrupole
  • Sensitivity:
    Inquire
  • Dynamic Range:
    Inquire
iCAP™ RQ ICP-MS
Thermo Fisher Scientific
  • Mass Analyzer:
    Single Quadrupole
  • Sensitivity:
    Inquire
  • Dynamic Range:
    >9 orders of magnitude (<1 to >1 x 109 cps)
Citations:
(1)
Neoma™ MS/MS MC-ICP-MS
Thermo Fisher Scientific
  • Mass Analyzer:
    Inquire
  • Sensitivity:
    Inquire
  • Dynamic Range:
    Inquire
Neoma™ Multicollector ICP-MS
Thermo Fisher Scientific
  • Mass Analyzer:
    Inquire
  • Sensitivity:
    Inquire
  • Dynamic Range:
    Inquire
Thermo Scientific Element 2 HR-ICP-MS
Thermo Fisher Scientific
  • Mass Analyzer:
    Double-focusing magnetic sector; three resolution settings: R = 300, 4,000, 10,000; magnet jump time <150 ms (7Li–²³8U–7Li)
  • Sensitivity:
    >3×106 cps/ppb (¹¹5In) wet plasma with Jet Interface; >3–5×107 cps/ppb (¹¹5In) dry plasma
  • Dynamic Range:
    >9 orders of magnitude (>10? cps linear dynamic range)
Thermo Scientific Element XR HR-ICP-MS
Thermo Fisher Scientific
  • Mass Analyzer:
    Double-focusing magnetic sector; three resolution settings: R = 300, 4,000, 10,000; triple detection (SEM + Faraday + filter lens); auto-switch to Faraday above SEM range
  • Sensitivity:
    >3×106 cps/ppb (¹¹5In) wet plasma with Jet Interface; >3–5×107 cps/ppb (¹¹5In) dry plasma
  • Dynamic Range:
    >12 orders of magnitude (>10¹² cps linear dynamic range)
Thermo Scientific iCAP RQplus ICP-MS
Thermo Fisher Scientific
  • Mass Analyzer:
    Single quadrupole; QCell collision/reaction cell with He KED; three AGD modes for online matrix dilution
  • Sensitivity:
    Sub-ppt capability with AGD technology
  • Dynamic Range:
    Inquire
Thermo Scientific Neptune Plus MC-ICP-MS
Thermo Fisher Scientific
  • Mass Analyzer:
    Double-focusing magnetic sector (MC-ICP-MS); mass range 1–256 u; low/medium/high resolution modes; independent source and detector slit settings
  • Sensitivity:
    10–20× increase in desolvation mode via jet interface
  • Dynamic Range:
    High dynamic range with multi ion counting capability
Thermo Scientific™ iCAP™ MSX Inductively Coupled Plasma Mass Spectrometer (ICP-MS)
Thermo Fisher Scientific
  • Mass Analyzer:
    Inquire
  • Sensitivity:
    Inquire
  • Dynamic Range:
    Inquire
Thermo Scientific™ iCAP™ MTX Inductively Coupled Plasma Mass Spectrometer (ICP-MS)
Thermo Fisher Scientific
  • Mass Analyzer:
    Inquire
  • Sensitivity:
    Inquire
  • Dynamic Range:
    Inquire
Attom ES ICP-MS
Nu Instruments
  • Mass Analyzer:
    Single-collector double-focusing magnetic sector; mass range 1–260 u
  • Sensitivity:
    Inquire
  • Dynamic Range:
    9 orders of magnitude (pulse-counting multiplier with patented beam attenuation); 12 orders of magnitude with optional Faraday detector
Inquire
Nu Plasma 1700 HR-MC-ICP-MS
Nu Instruments
  • Mass Analyzer:
    Multi-collector double-focusing magnetic sector; 16 Faraday cups + up to 5 ion-counting detectors (SEM or Daly); mass range lithium to actinide series
  • Sensitivity:
    Inquire
  • Dynamic Range:
    Inquire
Inquire
Nu Sapphire MC-ICP-MS
Nu Instruments
  • Mass Analyzer:
    Multi-collector double-focusing magnetic sector; 16 Faraday cups + up to 6 ion-counting detectors (SEM or Daly); high-resolution and pseudo-high-resolution modes
  • Sensitivity:
    Inquire
  • Dynamic Range:
    Inquire
Inquire
Nu Sapphire XD MC-ICP-MS/MS
Nu Instruments
  • Mass Analyzer:
    Multi-collector double-focusing magnetic sector with MS/MS capability; XD collector array with up to 28 Faraday cups + up to 6 ion-counting detectors (SEM or Daly); mass range Li to U and beyond; 25% natural dispersion; dynamic range 0–75 Gcps (SEM to 10^10 O pre-amplifier)
  • Sensitivity:
    Inquire
  • Dynamic Range:
    0–75 Gcps (0–1200 V) from SEM to 10^10 O resistor pre-amplifier
Inquire
Plasma 3 MC-ICP-MS
Nu Instruments
  • Mass Analyzer:
    Multi-collector double-focusing magnetic sector; 16 Faraday cups + up to 6 ion-counting detectors (SEM or Daly); mass range lithium to actinide series
  • Sensitivity:
    Inquire
  • Dynamic Range:
    Inquire
Inquire
Vitesse ICP-MS
Nu Instruments
  • Mass Analyzer:
    Time-of-Flight (TOF); simultaneous full-spectrum acquisition; acquisition rate 33 kHz (full mass range) to 160 kHz (reduced mass range); spectrum readout time as low as 80 µs
  • Sensitivity:
    Inquire
  • Dynamic Range:
    10 orders of magnitude (patented ion beam attenuation system combined with MagneTOF detector)
Inquire
SPECTROGREEN MS
SPECTRO Analytical Instruments
  • Mass Analyzer:
    Single quadrupole; RF-only pre-filter; 200 mm length, 12 mm Mo rods; fully digital 10 kV power supply; hexapole CRC (He KED ~4 mL/min; H2 reaction mode); dual-stage electron multiplier; minimum integration time =100 µs/channel
  • Sensitivity:
    Inquire
  • Dynamic Range:
    10 orders of magnitude
Select up to 5 products from above to compare or request more information.

Tags:

Please Login or Register to Create Tags
  • Agilent Technologies
  • Analytik Jena
  • GBC Scientific Equipment
  • Nu Instruments
  • PerkinElmer
  • Shimadzu
  • SPECTRO Analytical Instruments
  • Thermo Fisher Scientific