Inductively Coupled Plasma Mass Spectrometer (ICP MS)

Inductively Coupled Plasma Mass Spectrometer (ICP MS) Inductively coupled plasma mass spectrometers (ICP-MS) utilize inductively coupled plasma for sample ionization and an MS for ion separation and quantification. The low detection limits and high productivity possible with ICP-MS are particularly useful for trace metal analysis and environmental testing. Common components of an ICP-MS system include a sample introduction system, an ion source, a vacuum system, a collision reaction cell, ion optics, a mass spectrometer (often a quadrupole), and a detector. An analytical working range of nine orders of magnitude, detection limits below the ppt range, and aptitude for isotopic analysis are hallmarks of ICP-MS. ICP-MS instruments are commonly configured for routine analyses, high-matrix interference samples, or specific applications, such as work in the semiconductor industry or medical and forensic toxicology fields. Also, be sure to consider any desired customization options, such as chromatographic coupling or use with organic solvents.

Find, compare, and request a quote for inductively coupled plasma mass spectrometers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

Showing 2 of 2 products
  • <<
  • >>
Get Quote for All
Select up to 5 products from below to compare or request more information.
OptiMass 9500 ICP-TOFMS
GBC Scientific Equipment
  • Mass Analyzer:
    Orthogonal acceleration Time-of-Flight (TOF); mass range 1–260 u; resolution 0.4 u (R =1200 at 238U); 30,000 full spectra/s
  • Sensitivity:
    Parts per trillion (ppt) detection limits; mass range 1–260 amu; >30,000 full spectra per second; resolution typically 1,200 or greater for 238U (0.4 amu)
  • Dynamic Range:
    Mass range 1 to 260 amu
OptiMass 9600 ICP-TOFMS
GBC Scientific Equipment
  • Mass Analyzer:
    Orthogonal acceleration Time-of-Flight (TOF) with Octopole Collision Cell (OCC); mass range 1–260 u; resolution 0.4 u (R =1200 at 238U); 30,000 full spectra/s
  • Sensitivity:
    Parts per trillion (ppt) detection limits; mass range 1–260 amu; >30,000 full spectra per second; resolution typically 1,200 or greater for 238U (0.4 amu)
  • Dynamic Range:
    Mass range 1 to 260 amu
Select up to 5 products from above to compare or request more information.

Tags:

Please Login or Register to Create Tags
  • Agilent Technologies
  • Analytik Jena
  • GBC Scientific Equipment
  • Nu Instruments
  • PerkinElmer
  • Shimadzu
  • SPECTRO Analytical Instruments
  • Thermo Fisher Scientific

Review Laboratory Products

Review the laboratory equipment you use and receive an Amazon gift card!

Submit a Review
Get the Latest Updates, Technology News and Trends, New Products, Promotions, Buying Tips, and More!

Note: Labcompare disclaims any information on this site.