Flow Cytometer

Flow cytometers are instruments used to analyze cells within a solution and provide multi-parameter analysis capabilities. A flow cytometer instrument is often comprised of a fluidic system to transport cells in solution, lenses and filters, as well as a laser or other light source to provide scattered and fluorescent light that is then analyzed by a detector. Flow cytometer detectors commonly include photodiodes or photomultiplier tubes. Used extensively throughout the life sciences industry, flow cytometers provide users with a wealth of information such as the determination of cell characteristics and function, biomarker discovery, treatment and diagnosis information, cell counting and or sorting, and many others. When comparing flow cytometers, ensure that the excitation wavelength and flow rate are compatible with your specific assay. Additionally, many flow cytometers can accommodate several sample formats such as tubes or microplates, and should be considered to ensure smooth integration with your current processes.

Find, compare, and request a quote for flow cytometers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

CompanyBeckman Coulter Life SciencesBeckman Coulter Life SciencesBeckman Coulter Life Sciences
ItemCytoFLEX LX Flow CytometerAQUIOS CL Flow CytometersNavios EX Flow Cytometers
Catalog NumberCytoFLEX LXAQUIOS CLNavios EX
Price
Flow Rate10 to 240 µL/minInquire10 to 70 µL/min
DescriptionThe CytoFLEX LX Flow Cytometer is an expansion of the CytoFLEX Platform.

This model expands research possibilities with up to six lasers and 21 color parameters. Six spatially separated lasers allows panels to be spread across the spectrum reducing cross talk and spectral overlap. All instruments in

... Read More
AQUIOS CL Overview

The AQUIOS CL is the first true Load & Go flow cytometer, combining sample preparation and analysis in one platform while optimizing the usage of limited laboratory space. With the intuitive technology that requires less training it increases productivity while reducing error-

... Read More
Powerful, Dependable Flow Cytometer

Strong and stable cytometer performance is fundamental when analyzing important clinical samples as every event matters. Designed specifically for the clinical laboratory the NAVIOS EX 10-color flow cytometer delivers proven reliability and stability performance

... Read More
Excitation Wavelength355 nm (20 mW), 375 nm (60 mW), 405 nm (80 mW), 488 nm (50 mW), 561 nm (30 mW), 638 nm (50 mW), 808 nm (60 mW)488 nm405 nm (80 mW), 488 nm (55 mW), 638 nm (50 mW)
Throughput30,000 events per second with 23 parameters4250 events/sec25,000 events/sec
Get Quote

Articles