A fluorescence spectrometer is a device to detect and analyze organic compounds. Used in biology, chemistry, and environmental science laboratories, the fluorescence spectrometer measures the fluorescence of a molecule to gather information about its components and chemical environment. The two main types of fluorescence spectrometers are filter fluorometers, which use filters to isolate the different types of light, and spectrofluorometers, which isolate the types of light with diffraction grating monochromators.
What to consider when choosing a fluorescence spectrometer?
When choosing a fluorescence spectrometer, consider the wavelengths it can analyze, the time analysis takes, and the amount of sample needed for analysis.Discover and compare Fluorescence Spectrometers:
Get Quote for All
Select up to 5 products from below to compare or request more information.
Sponsored Products
JASCO
- Zero order, 200 to 750 nm
- Excitation: Silicon photodiode
Emission: Photomultiplier tube - Excitation: 1.0 nm (at 546.1 nm)
Emission: 1.0 nm (at 546.1 nm) - RMS Noise: 8,000:1
Agilent Technologies
- 200–900 nm
- Red-sensitive Photomultiplier tube
- Inquire
Edinburgh Instruments Ltd
- Emission Wavelength Range 160 nm to 5500 nm
- Photomultipliers (UV - NIR), Analogue (NIR - MIR)
- 0.05 nm
- > 35,000:1 FSD
Edinburgh Instruments Ltd
- Excitation Wavelength 185 to 1000 nm; Emission Wavelength 200 to 1650 nm
- Photomultipliers (UV-NIR), InGaAs
- Inquire
- 10,000:1 FSD
Edinburgh Instruments Ltd
- 8000 to 350 cm -1
- DLaTGS
Additional detector fitted to the instrument optimising its spectral range:
Detector options include InSb, InGaAs, and MCT - 0.5 cm-1, 1 cm-1, 2 cm-1, 4 cm-1, 8 cm-1, 16 cm-1, 32 cm-1
- SNR ≥ 20,000:1
Edinburgh Instruments Ltd
- 200 to 1700 nm
- Inquire
- Inquire
- Inquire
Edinburgh Instruments Ltd
- Inquire
- Inquire
- Inquire
- Inquire
Edinburgh Instruments Ltd
- Inquire
- Inquire
- Inquire
- Inquire
JASCO
- Zero order, 200 to 750 nm
- Excitation: 1.0 nm (at 546.1 nm)
Emission: 1.0 nm (at 546.1 nm) - RMS Noise: 4,500:1
JASCO
- Zero order, 200 to 850 nm
- Excitation: 1.0 nm (at 546.1 nm)
Emission: 1.0 nm (at 546.1 nm) - RMS Noise: 8,500:1
JASCO
- Ex: Zero order, 200 to 850 nm
Em: Zero order, 200 to 980 nm - Excitation: 1.0 nm (at 546.1 nm)
Emission: 2.0 nm (at 546.1 nm) - RMS Noise: 3,500:1
Zolix Instruments Co., Ltd.
- Inquire
- TE-cooled PMT
- 0.1 nm
- Inquire
Select up to 5 products from above to compare or request more information.
Tags:
Please Login or Register to Create Tags
- Great Workhorse Instrument!
Agilent Technologies
Very amazed by how well this instrument operated. Within a year, this device was used almost daily. It had only one major issue, which was due to a power outage. We've had it pre-calibrated for ... Read Review