Atomic Absorption Spectrophotometer

Atomic Absorption Spectrophotometer Atomic absorption spectrophotometry analyzes the concentration of elements in a liquid sample based on energy absorbed from certain wavelengths of light (usually 190 to 900 nm). Atomic absorption spectrophotometers typically include a flame burner to atomize the sample (most commonly a hollow cathode lamp), a monochromator, and a photon detector. Depending on the model, some atomic absorption spectrometers are equipped with a turret or fixed lamp socket that can hold multiple lamps (up to eight) to reduce downtime between samples or allow for sequential analysis.

Typical sensitivity for an atomic absorption spectrometer using a flame burner is in the parts per million range. For trace analysis, a graphite furnace can be used in place of a flame burner to increase the sensitivity by several orders of magnitude (in the parts per billion range). Atomic absorption spectrophotometers are used in many industries including environmental testing, metal analysis, semiconductor manufacturing, petroleum and chemical production, and in pharmaceuticals, for example.

Find, compare, and request a quote for atomic absorption spectrophotometers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

Showing 22 of 22 products
  • <<
  • >>
Get Quote for All
Select up to 5 products from below to compare or request more information.
240Z AA Atomic Absorption Spectrometer
Agilent Technologies
  • Lamps:
    Single light source, up to 4 fixed lamp positions
  • Wavelength Range:
    Inquire
  • Lamp Type:
    Hollow Cathode and UltrAA lamp
  • Vaporization:
    Zeeman graphite tube atomizer
  • Sensitivity:
    Inquire
Citations:
(27)
280Z AA Atomic Absorption Spectrometer
Agilent Technologies
  • Lamps:
    Single light source, up to 8 fixed lamp positions
  • Wavelength Range:
    185-900 nm
  • Lamp Type:
    Hollow Cathode and UltrAA lamp
  • Vaporization:
    Zeeman graphite tube atomizer
  • Sensitivity:
    Inquire
Citations:
(12)
AA Duo Atomic Absorption Spectrometer
Agilent Technologies
  • Lamps:
    4 to 8 Lamps (depending on configuration)
  • Wavelength Range:
    185-900 nm range
  • Lamp Type:
    UltrAA Lamps
  • Vaporization:
    Flame/Hydride and Graphite Furnace
  • Sensitivity:
    Inquire
Citations:
(16)
AA240FS Fast Sequential AAS
Agilent Technologies
  • Lamps:
    4 Lamps
  • Wavelength Range:
    185 to 900 nm
  • Lamp Type:
    Hollow-Cathode and Deuterium
  • Vaporization:
    Flame
  • Sensitivity:
    Inquire
Citations:
(81)
AA280FS Atomic Absorption Spectrometer
Agilent Technologies
  • Lamps:
    8 Lamps
  • Wavelength Range:
    185 to 900 nm
  • Lamp Type:
    Hollow-Cathode and Deuterium
  • Vaporization:
    Flame
  • Sensitivity:
    Inquire
Citations:
(36)
contrAA® 800 D Atomic Absorption Spectrometry System
Analytik Jena
  • Lamps:
    Inquire
  • Wavelength Range:
    185-900 nm (continuous wavelength coverage up to 72 elements enabling access to all alternative absorption lines and molecular absorption lines e.g. PO, CS, GaF)
  • Lamp Type:
    Water-cooled Xenon short arc lamp
  • Vaporization:
    Flame and/or Graphite Furnace
  • Sensitivity:
    Flame: (Cu 324) 0.015 mg/l 1%Abs using a 10 cm burner head (air/acetylene)
    Graphite furnace: (Pb 283) 0.66 µg/l 1%Abs (for 20 µL, peak area evaluation)
Citations:
(2)
novAA® 800 D Analyzer
Analytik Jena
  • Lamps:
    Inquire
  • Wavelength Range:
    185 – 900 nm
  • Lamp Type:
    hollow cathode
  • Vaporization:
    flame and/or graphite furnace
  • Sensitivity:
    Flame: (Cu 324) 0.017 mg/L 1 %Abs using a 10 cm burner head (air/acetylene)
    Graphite furnace: (Pb 283) 0.79 µg/L 1 %Abs (for 20 µL, peak area evaluation)
ZEEnit 700 P Compact Tandem Spectrometer
Analytik Jena
  • Lamps:
    8-lamp turret
  • Wavelength Range:
    185 - 900 nm
  • Lamp Type:
    Hollow cathode
  • Vaporization:
    flame and graphite furnace
  • Sensitivity:
    Graphite furnace: 0.94 µg/L 1 %Abs (Pb 283)
    Flame: 0.017 mg/l 1%Abs (Cu 324)
Citations:
(20)
SavantAA Atomic Absorption Spectrometer
GBC Scientific Equipment
  • Lamps:
    8 (motorized turret with automatic lamp selection)
  • Wavelength Range:
    175 - 900 nm
  • Lamp Type:
    Hollow Cathode Lamp (HCL); Optional Super Lamp
  • Vaporization:
    Flame; Graphite Furnace; Hydride Generation
  • Sensitivity:
    >0.9 abs for 5 mg/L Cu with <0.5% RSD
SavantAA Zeeman Atomic Absorption Spectrometer
GBC Scientific Equipment
  • Lamps:
    8 (motorized turret with automatic lamp selection)
  • Wavelength Range:
    175 - 900 nm
  • Lamp Type:
    Hollow Cathode Lamp (HCL); Optional Super Lamp
  • Vaporization:
    Flame; Graphite Furnace
  • Sensitivity:
    >0.9 abs for 5 mg/L Cu with <0.5% RSD
XplorAA Dual Double Beam Atomic Absorption Spectrometer
GBC Scientific Equipment
  • Lamps:
    2 (manual) or 6 (motorized turret)
  • Wavelength Range:
    175 - 900 nm
  • Lamp Type:
    Hollow Cathode Lamp (HCL); Optional Super Lamp
  • Vaporization:
    Flame; Graphite Furnace; Hydride Generation
  • Sensitivity:
    Inquire
ZA3000 Polarized Zeeman Atomic Absorption Spectrophotometer
Hitachi High-Tech America, Inc.
  • Lamps:
    2 (dual photomultiplier detectors)
  • Wavelength Range:
    190 - 900 nm
  • Lamp Type:
    Hollow Cathode Lamp (HCL)
  • Vaporization:
    Flame; Graphite Furnace
  • Sensitivity:
    Inquire
ZA4000 Polarized Zeeman Atomic Absorption Spectrophotometer
Hitachi High-Tech America, Inc.
  • Lamps:
    4 (simultaneous, supports sequential multi-element measurement of up to 12 elements)
  • Wavelength Range:
    190 - 900 nm
  • Lamp Type:
    Hollow Cathode Lamp (HCL)
  • Vaporization:
    Flame; Graphite Furnace
  • Sensitivity:
    Inquire
PinAAcle 500 Flame Atomic Absorption Spectrometer
PerkinElmer
  • Lamps:
    4
  • Wavelength Range:
    180-900 nm
  • Lamp Type:
    Coded 2-inch Lumina cableless hollow cathode and patented electrodeless discharge lamps
  • Vaporization:
    Flame
  • Sensitivity:
    Inquire
Inquire
PinAAcle 900F Flame Atomic Absorption Spectrometer
PerkinElmer
  • Lamps:
    8
  • Wavelength Range:
    184-900 nm
  • Lamp Type:
    Lumina cableless hollow cathode and patented electrodeless discharge lamps
  • Vaporization:
    Flame
  • Sensitivity:
    Inquire
Inquire
PinAAcle 900H Flame/Hydride Atomic Absorption Spectrometer
PerkinElmer
  • Lamps:
    8-lamp mount with built-in power supplies for PerkinElmer cableless Lumina hollow cathode and patented electrodeless discharge lamps
  • Wavelength Range:
    184-900 nm
  • Lamp Type:
    Lumina hollow cathode lamps (HCL) and electrodeless discharge lamps (EDL)
  • Vaporization:
    Flame (air-acetylene or nitrous oxide-acetylene) and graphite furnace (HGA — Heated Graphite Atomizer)
  • Sensitivity:
    Inquire
Inquire
PinAAcle 900T Combined Flame/Furnace Atomic Absorption Spectrometer
PerkinElmer
  • Lamps:
    8-lamp mount with built-in power supplies for PerkinElmer cableless Lumina hollow cathode and patented electrodeless discharge lamps
  • Wavelength Range:
    184-900 nm
  • Lamp Type:
    Lumina hollow cathode lamps (HCL) and electrodeless discharge lamps (EDL)
  • Vaporization:
    Flame (air-acetylene or nitrous oxide-acetylene) and graphite furnace (THGA — Transversely Heated Graphite Atomizer)
  • Sensitivity:
    Inquire
Inquire
PinAAcle 900Z Zeeman Furnace Atomic Absorption Spectrometer
PerkinElmer
  • Lamps:
    8-lamp mount with built-in power supplies for PerkinElmer cableless Lumina hollow cathode and patented electrodeless discharge lamps
  • Wavelength Range:
    184-900 nm
  • Lamp Type:
    Lumina hollow cathode lamps (HCL) and electrodeless discharge lamps (EDL)
  • Vaporization:
    Graphite furnace only (THGA — Transversely Heated Graphite Atomizer)
  • Sensitivity:
    Inquire
Inquire
AA-7800 Atomic Absorption Spectrophotometer
Shimadzu
  • Lamps:
    8 lamps
  • Wavelength Range:
    185 to 900 nm
  • Lamp Type:
    Hollow Cathode
  • Vaporization:
    Flame and/or Graphite Furnace
  • Sensitivity:
    Inquire
Citations:
(2)
iCE 3300 AA Spectrometer
Thermo Fisher Scientific
  • Lamps:
    6 (coded, auto-aligning carousel)
  • Wavelength Range:
    180–900 nm
  • Lamp Type:
    Hollow Cathode Lamp (HCL)
  • Vaporization:
    Flame (50 mm Ti burner)
  • Sensitivity:
    Quadline deuterium background correction with guaranteed performance; spectral bandwidths 0.2, 0.5, and 1.0 nm; Ebert monochromator
iCE 3400 AA Spectrometer
Thermo Fisher Scientific
  • Lamps:
    6 (coded, auto-aligning carousel)
  • Wavelength Range:
    180–900 nm
  • Lamp Type:
    Hollow Cathode Lamp (HCL)
  • Vaporization:
    Graphite Furnace, Vapor
  • Sensitivity:
    Guaranteed Quadline deuterium and AC Zeeman background correction; Echelle monochromator; dynamic optical temperature control up to 3000 degrees C/sec
iCE 3500 AAS Atomic Absorption Spectrometer
Thermo Fisher Scientific
  • Lamps:
    6 (coded, auto-aligning carousel)
  • Wavelength Range:
    180-900 nm
  • Lamp Type:
    Dual atomizer (flame and furnace)
  • Vaporization:
    Flame (air/acetylene and nitrous oxide/acetylene) and Graphite Furnace
  • Sensitivity:
    Guaranteed Quadline deuterium or AC Zeeman background correction; Echelle monochromator; dynamic optical temperature feedback up to 3000 degrees C/sec; Extended Lifetime Cuvettes (ELC)
Select up to 5 products from above to compare or request more information.

Tags:

Please Login or Register to Create Tags
  • <<
  • >>
  • Agilent Technologies
  • Analytik Jena
  • GBC Scientific Equipment
  • Hitachi High-Tech America, Inc.
  • PerkinElmer
  • Shimadzu
  • Thermo Fisher Scientific

Review Laboratory Products

Review the laboratory equipment you use and receive an Amazon gift card!

Submit a Review
Get the Latest Updates, Technology News and Trends, New Products, Promotions, Buying Tips, and More!