Comprising two components, a liquid-phase separation system and a mass spectrometer, liquid chromatograph mass spectrometers (LC MS instruments) couple sample fractionation and analysis. The separation can be accomplished via standard liquid chromatography, HPLC, UPLC, or even nano-LC. Any liquid-phase separation will do, so long as its output can be directed into the mass analyzer (for instance, via an electrospray ionization source). The mass spectrometer is similarly flexible, ranging from the simplest single quadrupole to a Fourier transform ion cyclotron resonance instrument. Just remember, in a liquid chromatograph mass spectrometer the column flow is continuous, meaning the mass analyzer must be fast enough to thoroughly analyze one peak before the next one comes off the column. And, unlike with MALDI MS, once a peak is analyzed, it’s gone.
Your search for LC/MS returned 31 results.
Get Quote for All
Select up to 5 products from below to compare or request more information.
Sponsored Products
PerkinElmer
- ESI, APCI
- Triple Quadrupole
- Inquire
- Inquire
Shimadzu
- Inquire
- Inquire
- Inquire
- Inquire
Shimadzu
- ESI probe with focus electrodes
- Triple quadrupole
- Max. 30,000 u/sec (in all scan modes)
(0.1 u step: 300,000 data points/sec) - R < 0.7 u FWHM and adjustable to 0.5 u
JASCO
- Inquire
- Inquire
- 10,000 m/z units/sec (compatible with UHPLC)
- 0.5 to 0.7 m/z units (FWHM) at 1,000 m/z units/sec over entire acquisition range
Thermo Fisher Scientific
- Inquire
- Inquire
- Inquire
- Inquire
SCIEX
- OptiFlow® Pro Ion Source
- Triple quadrupole
- 20,000 Da/s
- Up to 3100 for mass 922 in LIT mode 1000 Da/s (0.3 Da)
Tune to a peak width of 0.5 Da for TQ mode
SCIEX
- Inquire
- Inquire
- Inquire
- Inquire
Thermo Fisher Scientific
- Inquire
- UHMR Hybrid Quadrupole-Orbitrap™
- up to 12 Hz at resolution setting of 12,500 at m/z 400
- 200,000 at m/z 400
SCIEX
- Electrospray Ionization
- Inquire
- Up to 3 samples per second
- Inquire
Shimadzu
- ESI, APCI, Dual Ionization
- Q1 & Q3 are molybdenum hyperbolic mass filters with pre-rods; Q1 includes post-rods
- 30,000 u/sec
- R < 0.7 u FWHM
Shimadzu
- Inquire
- Inquire
- Inquire
- Inquire
Thermo Fisher Scientific
- API, HESI
- Single quadrupole
- Up to 20,000 Da/sec.
- Inquire
Shimadzu
- ESI, APCI, Dual Ionization
- Q1 & Q3 are molybdenum hyperbolic mass filters with pre-rods; Q1 includes post-rods
- 30,000 u/sec
- R < 0.7 u FWHM
Thermo Fisher Scientific
- APCI, H-ESI
- Orbitrap
- Up to 12 Hz
- up to 140,000 FWHM
Thermo Fisher Scientific
- Inquire
- Inquire
- Inquire
- Inquire
Thermo Fisher Scientific
- Inquire
- Inquire
- Inquire
- Inquire
Thermo Fisher Scientific
- APCI, H-ESI
- Hybrid Quadrupole / Orbitrap
- Up to 12 Hz
- up to 280,000 FWHM
SCIEX
- APCI and ESI modes
- TOF
- up to 25 Hz (25 spectra per second)
- Equal to or greater than 42,000 (FWHM) measured on the [M+6H]6+ charge isotope cluster for bovine insulin at m/z 956
Thermo Fisher Scientific
- Inquire
- Inquire
- Inquire
- Inquire
Thermo Fisher Scientific
- Inquire
- Inquire
- OTMSn up to 40 Hz ITMSn up to 45 Hz
- 7500 to 500,000 (FWHM) at m/z 200
Thermo Fisher Scientific
- Inquire
- Inquire
- Inquire
- Inquire
Thermo Fisher Scientific
- Inquire
- Inquire
- Inquire
- 7500 to 500,000 (FWHM) at m/z 200
Thermo Fisher Scientific
- Inquire
- Inquire
- Inquire
- 480,000 at m/z 195
Thermo Fisher Scientific
- HESI
- Orbitrap
- Inquire
- 7500-500,000 (FWHM) at m/z 200
SCIEX
- Turbo V ion source with twin sprayer ESI probe
and twin sprayer APCI probe - QTOF
- Up to 25 Hz (25 spectra per second)
- Equal to or greater than 42,000 (FWHM) measured on the (M+6H)6+ charge isotope cluster for bovine insulin at m/z 956
Shimadzu
- ESI, APCI, Dual Ionization
- Single Quadrupole
- 15,000 u/sec
- R = 2 M
SCIEX
- Inquire
- Inquire
- Inquire
- Inquire
Shimadzu
- ESI, APCI, Dual Ionization
- Single Quadrupole
- 15,000 u/sec
- Inquire
Thermo Fisher Scientific
- Inquire
- Inquire
- Inquire
- Inquire
Thermo Fisher Scientific
- Inquire
- Inquire
- Inquire
- 7500 to 480,000 (FWHM) at m/z 200
Thermo Fisher Scientific
- Inquire
- Inquire
- Inquire
- Inquire
Select up to 5 products from above to compare or request more information.
Tags:
Please Login or Register to Create Tags
- The Best MS/MS Proteomics System.
Thermo Fisher Scientific
For an Orbitrap instrument, the Exploris series is the cutting-edge. The Exploris 240, has the same precise mass efficiency as the top-of-the-line Orbitraps, in particular, has a good sensitivity and ... Read Review - Superb Performance & Accuracy
Thermo Fisher Scientific
The Orbitrap Exploris 120 mass spectrometer is the most reliable source for achieving high data quality and comprehensive quantitative information to simplify our material testing analysis. It comes ... Read Review