LC MS Instrument

Comprising two components, a liquid-phase separation system and a mass spectrometer, liquid chromatograph mass spectrometers (LC MS instruments) couple sample fractionation and analysis. The separation can be accomplished via standard liquid chromatography, HPLC, UPLC, or even nano-LC. Any liquid-phase separation will do, so long as its output can be directed into the mass analyzer (for instance, via an electrospray ionization source). The mass spectrometer is similarly flexible, ranging from the simplest single quadrupole to a Fourier transform ion cyclotron resonance instrument. Just remember, in a liquid chromatograph mass spectrometer the column flow is continuous, meaning the mass analyzer must be fast enough to thoroughly analyze one peak before the next one comes off the column. And, unlike with MALDI MS, once a peak is analyzed, it’s gone.

Showing 6 of 6 products
  • <<
  • >>
Get Quote for All
Select up to 5 products from below to compare or request more information.
Echo® MS system
SCIEX
  • Ionization Method(s):
    Electrospray Ionization
  • Mass Analyzer:
    Inquire
  • Scanning Speed:
    Up to 3 samples per second
  • Resolution:
    Inquire
Citations:
(7)
Intabio ZT system
SCIEX
  • Ionization Method(s):
    Inquire
  • Mass Analyzer:
    Inquire
  • Scanning Speed:
    Inquire
  • Resolution:
    Inquire
SCIEX Triple Quad 7500 system
SCIEX
  • Ionization Method(s):
    OptiFlow® Pro Ion Source
  • Mass Analyzer:
    Triple quadrupole
  • Scanning Speed:
    20,000 Da/s
  • Resolution:
    Up to 3100 for mass 922 in LIT mode 1000 Da/s (0.3 Da)
    Tune to a peak width of 0.5 Da for TQ mode
Citations:
(1)
SelexION Differential Mobility Spectrometry
SCIEX
  • Ionization Method(s):
    Inquire
  • Mass Analyzer:
    Inquire
  • Scanning Speed:
    Inquire
  • Resolution:
    Inquire
Citations:
(145)
X500R QTOF system
SCIEX
  • Ionization Method(s):
    Turbo V ion source with twin sprayer ESI probe
    and twin sprayer APCI probe
  • Mass Analyzer:
    QTOF
  • Scanning Speed:
    Up to 25 Hz (25 spectra per second)
  • Resolution:
    Equal to or greater than 42,000 (FWHM) measured on the (M+6H)6+ charge isotope cluster for bovine insulin at m/z 956
Citations:
(114)
ZenoTOF 7600 system
SCIEX
  • Ionization Method(s):
    APCI and ESI modes
  • Mass Analyzer:
    TOF
  • Scanning Speed:
    up to 25 Hz (25 spectra per second)
  • Resolution:
    Equal to or greater than 42,000 (FWHM) measured on the [M+6H]6+ charge isotope cluster for bovine insulin at m/z 956
Citations:
(11)
Select up to 5 products from above to compare or request more information.

Tags:

Please Login or Register to Create Tags

Articles

  • <<
  • >>
  • JASCO
  • PerkinElmer
  • SCIEX
  • Shimadzu
  • Thermo Fisher Scientific