Spectrophotometers are used to measure the concentration of a known substance in a solution. They do this by passing a light through the substance and measuring light intensity as a function of wavelength. Either single beam or double beam spectrophotometers can be purchased. In a single beam spectrophotometer, a reference standard is used to measure light intensity before and after the sample is loaded. For double beam spectrophotometers the beam is split with one beam passing through the standard and the other through the sample to compare intensities. While single beam spectrophotometers are typically less expensive and have higher sensitivity, double beam spectrophotometers tend to be more stable and easier to use. Spectrophotometers are important pieces of equipment in chemistry, physics, biochemistry, clinical, and materials testing labs.

Find, compare, and request a quote for spectrophotometers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

Showing 10 of 10 products
  • <<
  • >>
Get Quote for All
Select up to 5 products from below to compare or request more information.
CPL-300 Circularly Polarized Luminescence Spectrophotometer
JASCO
  • Type:
    Circularly Polarized Luminescence
  • Wavelength Range:
    250 to 850 nm (Optional: 400 to 1,100 nm with PMT detector)
  • Optical System:
    Double prism monochromators for both excitation and emission optics / Piezoelastic modulator / Lock-in amplifier
  • Resolution:
    Wavelength Resolution: 0.025 nm
    CPL Resolution: 0.00001 mdeg
Citations:
(48)
FVS-6000 Vibrational Circular Dichroism Spectrometer
JASCO
  • Type:
    Circular Dichroism
  • Wavelength Range:
    3,200 to 850 cm-1 (Optional: 4,000 to 750 cm-1)
  • Optical System:
    28° Michelson interferometer, with gold coated corner-cube mirrors. mechanical bearing, temperature stabilized / KRS-5 Polarizer /
  • Resolution:
    0.5 to 16 cm-1
Citations:
(37)
Figures:
(1)
J-1100 Circular Dichroism Spectrophotometer
JASCO
  • Type:
    Circular Dichroism
  • Wavelength Range:
    180 to 600 nm
  • Optical System:
    Double-prism polarizing monochromator / J-1700: Double-prism polarizing monochromator and grating monochromator
  • Resolution:
    Wavelength Resolution: 0.025 nm / CD Resolution: 0.00001 mdeg
Citations:
(126)
J-1500 Circular Dichroism Spectrophotometer
JASCO
  • Type:
    Circular Dichroism
  • Wavelength Range:
    J-1500: 163 to 950 nm (Option: 163 to 1600 nm)
  • Optical System:
    Double-prism polarizing monochromator / J-1700: Double-prism polarizing monochromator and grating monochromator
  • Resolution:
    Wavelength Resolution: 0.025 nm / CD Resolution: 0.00001 mdeg
Citations:
(>1k)
Figures:
(21)
J-1700 Circular Dichroism Spectrophotometer
JASCO
  • Type:
    Circular Dichroism
  • Wavelength Range:
    163 to 2500 nm (Option: 163 to 950 nm (PMT) / Option: 900 to 2500 nm (InGaAs)
  • Optical System:
    Double-prism polarizing monochromator and grating monochromator
  • Resolution:
    Wavelength Resolution: 0.025 nm / CD Resolution: 0.00001 mdeg
Citations:
(24)
V-730 UV-Visible Spectrophotometer
JASCO
  • Type:
    UV-Visible
  • Wavelength Range:
    190 to 1,100 nm
  • Optical System:
    Rowland off-circle arrangement
    Single monochromator
    Double beam type
  • Resolution:
    =BS8
Citations:
(572)
V-750 UV-Visible Spectrophotometer
JASCO
  • Type:
    UV-Visible
  • Wavelength Range:
    190 to 900 nm
  • Optical System:
    Czerny-Turner mount
    Double monochromator
    Fully symmetrical double beam type
  • Resolution:
    =BS9
Citations:
(455)
Figures:
(1)
V-760 UV-Visible Spectrophotometer
JASCO
  • Type:
    UV-Visible
  • Wavelength Range:
    187 to 900 nm
  • Optical System:
    Czerny-Turner mount
    Single monochromator
    Fully symmetrical double beam type
  • Resolution:
    =BS10
Citations:
(89)
V-770 UV-Vis/NIR Spectrophotometer
JASCO
  • Type:
    UV-Visible/NIR
  • Wavelength Range:
    190 to 2,700 nm (3,200 nm, option)
  • Optical System:
    Czerny-Turner mount
    Single monochromator
    Fully symmetrical double beam type
  • Resolution:
    =BS11
Citations:
(522)
Figures:
(1)
V-780 UV-Vis/NIR Spectrophotometer
JASCO
  • Type:
    UV-Visible/NIR
  • Wavelength Range:
    190 to 1,600 nm
  • Optical System:
    Czerny-Turner mount
    Single monochromator
    Fully symmetrical double beam type
  • Resolution:
    =BS12
Citations:
(42)
Select up to 5 products from above to compare or request more information.

Tags:

Please Login or Register to Create Tags
  • <<
  • >>
JASCO
FVS-6000
3
1 Figure from 37 Publications
JASCO
J-1500
8
21 Figures from 1257 Publications
JASCO
V-750
11
1 Figure from 455 Publications
JASCO
V-770
1
1 Figure from 522 Publications
Showing 4 of 4 products
  • <<
  • >>
  • Agilent Technologies
  • Berthold Technologies GmbH & Co. KG
  • DeNovix Inc.
  • Edinburgh Instruments Ltd
  • JASCO
  • Mettler-Toledo GmbH
  • Molecular Devices, LLC
  • Shimadzu
  • Thermo Fisher Scientific
Get the Latest Updates, Technology News and Trends, New Products, Promotions, Buying Tips, and More!

Note: Labcompare disclaims any information on this site.