Atomic absorption spectrophotometry analyzes the concentration of elements in a liquid sample based on energy absorbed from certain wavelengths of light (usually 190 to 900 nm). Atomic absorption spectrophotometers typically include a flame burner to atomize the sample (most commonly a hollow cathode lamp), a monochromator, and a photon detector. Depending on the model, some atomic absorption spectrometers are equipped with a turret or fixed lamp socket that can hold multiple lamps (up to eight) to reduce downtime between samples or allow for sequential analysis.
Typical sensitivity for an atomic absorption spectrometer using a flame burner is in the parts per million range. For trace analysis, a graphite furnace can be used in place of a flame burner to increase the sensitivity by several orders of magnitude (in the parts per billion range). Atomic absorption spectrophotometers are used in many industries including environmental testing, metal analysis, semiconductor manufacturing, petroleum and chemical production, and in pharmaceuticals, for example.
Get Quote for All
Select up to 5 products from below to compare or request more information.
- Wavelength Range: Inquire
- Lamp Type: UltrAA lamp
- Lamps: Single light source, up to 8 fixed lamp positions
- Vaporization: Zeeman graphite tube atomizer
- Wavelength Range: Inquire
- Lamp Type: UltrAA lamp
- Lamps: Single light source, up to 8 fixed lamp positions
- Vaporization: Zeeman graphite tube atomizer
- Wavelength Range: 185 to 900 nm
- Lamp Type: Deuterium
- Lamps: 6 Lamp Turret (with Auto-Switch)
- Vaporization: Flame, Graphite Furnace or Vapour Generation
- Wavelength Range: 190 to 900 nm
- Lamp Type: Hollow Cathode
- Lamps: 2 Lamps
- Vaporization: Inquire
- Wavelength Range: 190 to 900 nm
- Lamp Type: Hollow-Cathode and Deuterium
- Lamps: 3 Lamp Turret
- Vaporization: Flame, Furnace, and Hydride
- Wavelength Range: 190 to 900 nm
- Lamp Type: Hollow-Cathode and Deuterium
- Lamps: 3 Lamp Turret
- Vaporization: Inquire
- Wavelength Range: 190 to 900 nm
- Lamp Type: Hollow-Cathode and Deuterium
- Lamps: 2 Lamps
- Vaporization: Flame Air/C2H2 and N2O/C2H2 burners
- Wavelength Range: 185 to 900 nm
- Lamp Type: Hollow-Cathode and Deuterium
- Lamps: 6 Lamp Turret
- Vaporization: Flame and/or Graphite Furnace
- Wavelength Range: 253.7 nm
- Lamp Type: Hg Lamp
- Lamps: Inquire
- Vaporization: Inquire
Inquire
- Wavelength Range: 190 to 900 nm
- Lamp Type: Hollow Cathode and Deuterium Arc Lamp
- Lamps: 8 (Hollow Cathode Lamps)
- Vaporization: Flame (Air/Acetylene, N2O/Acetylene and Air/LPG)
Inquire
- Wavelength Range: 190 to 900 nm
- Lamp Type: Hollow Cathode and Deuterium Arc Lamp
- Lamps: 8 (Hollow Cathode Lamps)
- Vaporization: Flame and Graphite Furnace
Inquire
- Wavelength Range: 190 to 900 nm
- Lamp Type: Hollow Cathode and Deuterium Arc Lamp
- Lamps: 8 (Hollow Cathode Lamps)
- Vaporization: Graphite Furnace
Inquire
- Wavelength Range: 190 to 900 nm
- Lamp Type: Hollow Cathode and Deuterium Arc Lamp
- Lamps: 8 (Hollow Cathode Lamps)
- Vaporization: Flame and Hydride
Inquire
- Wavelength Range: 180 to 900 nm
- Lamp Type: Quadline Deuterium
- Lamps: 6
- Vaporization: Flame or Graphite Furnace
Inquire
- Wavelength Range: 180 to 900 nm
- Lamp Type: Quadline Deuterium
- Lamps: 6
- Vaporization: Flame, Graphite
Furnace
Inquire