In Raman microscopy, also called confocal Raman microscopy, an optical microscope and a Raman spectrometer are combined into one instrument in order to provide high resolution images of small samples. This high resolution imaging has applications that include materials science, earth science, cell biology, medicine, cosmetics, and art analysis.
A Raman microscope consists of a basic optical microscope, a Raman spectrometer, a laser, a light source, and a detector such as a CCD camera. The optical microscope uses light to magnify and identify samples while the Raman spectrometer scatters light and measures the excitation vibration. When selecting a microscope, it is important to consider the qualities of each of the microscope's components and their optimal configuration for a particular application.
Find, compare, and request a quote for Raman and confocal Raman microscopes across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
Your search for Raman microscope returned 19 results.
Get Quote for All
Select up to 5 products from below to compare or request more information.
Sponsored Products
WITec GmbH
- Confocal Raman Imaging Microscopy
- CCD/EMCCD
- Multiple Laser Sources
Thermo Fisher Scientific
- Frequency-stabilized single mode, Multiple transverse mode
- Grating
- 532 nm Diode-pumped, solid state (DPSS), 633 nm HeNe gas, 780 nm Frequency-stabilized single mode diode laser, 780 nm Multiple transverse mode narrow-spectrum diode
Bruker Optics
- FT-Raman spectrometer
- InGaAs detector or Ge diode detector
- Diode-pumped, air-cooled Nd:YAG laser source
Edinburgh Instruments Ltd
- Confocal Raman, Photoluminescence, Temperature Control, Automatic Mapping, Polarisation
- High sensitivity ultra low noise CCD
1650 x 200 pixels, TE-cooled -60oC (standard) OR
2000 x 256 pixels, TE-cooled -60oC (enhanced sensitivity and spectral range) OR EMCCD (fast mapping applications) OR NIR Detector Array (spectral range up to 1700 nm) - Up to 3 narrow-band lasers including: 532 nm, 638 nm, 785 nm
Other wavelengths available on request
WITec GmbH
- Correlative Raman-SEM Imaging
- CCD/EMCCD
- Multiple Laser Sources
WITec GmbH
- Confocal Raman Imaging Microscopy
- CCD/EMCCD
- Multiple Laser Sources
Bruker Optics
- Confocal Raman, Automatic Fluorescence
- Grating
- Multiple laser sources
Edinburgh Instruments Ltd
- Confocal Raman, FLIM, Photoluminescence, Temperature Control, Automatic Mapping, Polarisation
- High sensitivity ultra low noise spectroscopy CCD
1650 x 200 pixels, TE-cooled -60°C (standard) OR 2000 x 256 pixels, TE-cooled -60°C (enhanced sensitivity and spectral range) OR EMCCD (fast mapping applications) OR NIR Detector Array (spectral range up to 1700 nm) - Up to 5 integrated narrow-band lasers: 532 nm, 638 nm, 785 nm typically used. Additional lasers from UV to NIR are available. External lasers can be integrated.
WITec GmbH
- Confocal Raman Microscopy
- CCD/EMCCD
- Multiple Laser Sources
Zolix Instruments Co., Ltd.
- Confocal Raman Imaging
- Inquire
- Inquire
JASCO
- Backscattering
- Air-cooled Peltier CCD detector (Max.-60°C)
1650 x 200 pixel, 16 µm x 16 µm, Visible to NIR - Standard: 532 nm, 20 mW
Optional lasers: 405, 442, 457, 488, 514.5, 532, 633, 785, 1064 nm, etc.
*Red wavelengths are recommended lasers.
*In case of 1064 nm, detector needs to be changed to InGaAs.
WITec GmbH
- Confocal Raman Imaging
- Optical Profilometer
- Multiple Laser Sources
JASCO
- Backscattering
- 4-Stage Peltier Cooled CCD Detector (UV-NIR range, 1,024 × 255 pixel)
- Standard: 532 nm, 50 mW
Optional lasers: 244, 266, 325, 355, 442, 488, 514.5, 633, 660, 785, 1064 nm, etc.
*Red wavelengths are recommended lasers.
*In case of 1064 nm, detector needs to be changed to InGaAs.
JASCO
- Backscattering
- 4-Stage Peltier Cooled CCD Detector (UV-NIR range, 1,024 × 255 pixel)
- Standard: 532 nm, 50 mW
Optional lasers: 244, 266, 325, 355, 442, 488, 514.5, 633, 660, 785, 1064 nm, etc.
*Red wavelengths are recommended lasers.
*In case of 1064 nm, detector needs to be changed to InGaAs.
Shimadzu
- Infrared and Raman
- T2SL and TGS detector
- Equipped standard with 532 nm and 785 nm lasers
JASCO
- Backscattering
- 4-Stage Peltier Cooled CCD Detector (UV-NIR range, 1,024 × 255 pixel)
- Standard: 532 nm, 50 mW
Optional lasers: 244, 266, 325, 355, 442, 488, 514.5, 633, 660, 785, 1064 nm, etc.
*Red wavelengths are recommended lasers.
*In case of 1064 nm, detector needs to be changed to InGaAs.
JASCO
- Backscattering
- 4-Stage Peltier Cooled CCD Detector (UV-NIR range, 1,024 × 255 pixel)
- Standard: 532 nm, 50 mW
Optional lasers: 244, 266, 325, 355, 442, 488, 514.5, 633, 660, 785, 1064 nm, etc.
*Red wavelengths are recommended lasers.
*In case of 1064 nm, detector needs to be changed to InGaAs.
Select up to 5 products from above to compare or request more information.